Research
Print page Print page
Switch language
Rigshospitalet - a part of Copenhagen University Hospital
Published

Surgical Results and Complications of Cochlear Implantation in Far-Advanced Otosclerosis

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Audiovestibular Loss of Function Correlates in Vestibular Schwannomas

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Contemporary Molecular Biology of Sporadic Vestibular Schwannomas: A Systematic Review and Clinical Implications

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Morphological evidence of biofilm in chronic obstructive sialadenitis

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. The Natural History of Hearing Loss in Pendred Syndrome and Non-Syndromic Enlarged Vestibular Aqueduct

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Language outcome in children with congenital hearing impairment: The influence of etiology

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Facial nerve schwannomas presenting with vestibular dysfunction: a case series

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. The Effect of a Distributed Virtual Reality Simulation Training Program on Dissection Mastoidectomy Performance

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. A mechanoelectrical mechanism for detection of sound envelopes in the hearing organ

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

OBJECTIVE: To report surgical results and complications of cochlear implantation in patients with far-advanced otosclerosis (FAO).

MATERIALS AND METHODS: This was a retrospective chart review of surgical results in terms of electrode insertion as well as peri- and postoperative complications. Ten cochlear implantations (CIs) were performed in eight patients with FAO. A prior stapedotomy had been performed in all cases.

RESULTS: Full electrode insertion was achieved in nine of the 10 operations (90%) and partial insertion in one operation. An unintended opening of the vestibule during drilling was the only perioperative complication. Postoperative complications occurred as two cases of vertigo (one prolonged). No chorda tympani syndrome and no cases of facial nerve stimulation were noted.

CONCLUSION: Although based on a limited number of cases, we conclude that full electrode insertion can be achieved in almost all cases and that major complications are infrequent in CI in patients with FAO. Postoperative vertigo appears to be the most commonly occurring complication.

Original languageEnglish
JournalJournal of Laryngology and Otology
Volume13
Issue number3
Pages (from-to)304-307