Research
Print page Print page
Switch language
Rigshospitalet - a part of Copenhagen University Hospital
Published

Reduced accuracy of MRI deep grey matter segmentation in multiple sclerosis: an evaluation of four automated methods against manual reference segmentations in a multi-center cohort

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Frequency of fatigue and its changes in the first 6 months after traumatic brain injury: results from the CENTER-TBI study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Characteristic muscle signatures assessed by quantitative MRI in patients with Bethlem myopathy

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Physical activity in myotonic dystrophy type 1

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. European muscle MRI study in limb girdle muscular dystrophy type R1/2A (LGMDR1/LGMD2A)

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Fibrinogen: A potential biomarker for predicting disease severity in multiple sclerosis

    Research output: Contribution to journalReviewpeer-review

  2. Highly sensitive quantification of optic neuritis intrathecal biomarker CXCL13

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Aggressive multiple sclerosis (2): Treatment

    Research output: Contribution to journalReviewpeer-review

  • MAGNIMS Study Group
View graph of relations

BACKGROUND: Deep grey matter (DGM) atrophy in multiple sclerosis (MS) and its relation to cognitive and clinical decline requires accurate measurements. MS pathology may deteriorate the performance of automated segmentation methods. Accuracy of DGM segmentation methods is compared between MS and controls, and the relation of performance with lesions and atrophy is studied.

METHODS: On images of 21 MS subjects and 11 controls, three raters manually outlined caudate nucleus, putamen and thalamus; outlines were combined by majority voting. FSL-FIRST, FreeSurfer, Geodesic Information Flow and volBrain were evaluated. Performance was evaluated volumetrically (intra-class correlation coefficient (ICC)) and spatially (Dice similarity coefficient (DSC)). Spearman's correlations of DSC with global and local lesion volume, structure of interest volume (ROIV), and normalized brain volume (NBV) were assessed.

RESULTS: ICC with manual volumes was mostly good and spatial agreement was high. MS exhibited significantly lower DSC than controls for thalamus and putamen. For some combinations of structure and method, DSC correlated negatively with lesion volume or positively with NBV or ROIV. Lesion-filling did not substantially change segmentations.

CONCLUSIONS: Automated methods have impaired performance in patients. Performance generally deteriorated with higher lesion volume and lower NBV and ROIV, suggesting that these may contribute to the impaired performance.

Original languageEnglish
JournalJournal of Neurology
Volume267
Issue number12
Pages (from-to)3541-3554
Number of pages14
ISSN0340-5354
DOIs
Publication statusPublished - Dec 2020

ID: 61516285