Research
Print page Print page
Switch language
Rigshospitalet - a part of Copenhagen University Hospital
Published

Optimizing Pedicle Subtraction Osteotomy Techniques: A New Reduction Plier to Increase Technical Safety and Angular Reduction Efficiency

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Ventriculoperitoneal Shunt Complications in the European Idiopathic Normal Pressure Hydrocephalus Multicenter Study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Stereotactic Brain Biopsy in Eloquent Areas Assisted by Navigated Transcranial Magnetic Stimulation: a Technical Case Report

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Is pseudarthrosis after spinal instrumentation caused by a chronic infection?

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. A comparison of mortality and morbidity between complex and degenerative spine surgery in prospectively collected data from 2280 procedures

    Research output: Contribution to journalConference abstract in journalResearchpeer-review

  3. Sagittal Alignment After Surgical Treatment of Adolescent Idiopathic Scoliosis-Application of the Roussouly Classification

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: Pedicle subtraction osteotomy (PSO) is a technically demanding surgery. There is room for development of osteotomy reduction instruments like the one we present in this study, to better guide angular correction and closure of the osteotomy line.

OBJECTIVE: To present a new surgical instrument that optimizes PSOs of the thoracolumbar spine.

METHODS: Seventeen consecutive patients have been treated at 3 different European University Hospitals. All underwent a PSO of the lumbar spine to treat major sagittal imbalance. The amount of vertebral angular correction needed was calculated using the full balance integrated (FBI) method. A special plier, which allows to safely control the angular correction, was used intraoperatively. Preoperative and early postoperative global sagittal balance parameters were compared.

RESULTS: The mean preoperative calculated correction angle (FBI) was 33.8°; the mean postoperative correction obtained was 32.1°. Lumbar lordosis was statistically greater than preoperatively (55.8° vs 19.4°, P < .0001). The global sagittal balance was improved, as shown by the increase of the spino-sacral angle from 122° preoperatively to 128° postoperatively (P = .0547). None of the patients had an intraoperative or early postoperative neurologic complication. There were no mechanical intraoperative complications during correction nor at the first postoperative follow-up.

CONCLUSION: The advantages of the instrument are safe, precise, and efficient reduction, by a rotation of the pedicle screws close to the osteotomy line, thus avoiding collapse and lack of correction, complications usually seen with the conventional technique. Further prospective studies are needed to confirm these results.

Original languageEnglish
JournalOperative neurosurgery (Hagerstown, Md.)
Volume16
Issue number3
Pages (from-to)383-388
ISSN2332-4252
DOIs
Publication statusPublished - 2019

Bibliographical note

Copyright © 2018 by the Congress of Neurological Surgeons.

    Research areas

  • Osteotomy reduction, Pedicle subtraction osteotomy, Sagittal balance, Technique

ID: 56468320