Research
Print page Print page
Switch language
Rigshospitalet - a part of Copenhagen University Hospital
Published

Irregular breathing during 4DCT scanning of lung cancer patients: Is the midventilation approach robust?

Research output: Contribution to journalJournal articleResearchpeer-review

  1. [OA023] Multiparametric MRI measurements of renal perfusion and oxygenation

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. The impact of technology on the changing practice of lung SBRT

    Research output: Contribution to journalReviewResearchpeer-review

  1. An investigative expansion of a competing risk model for first failure site in locally advanced non-small cell lung cancer

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Pre-radiotherapy daily exercise training in non-small cell lung cancer: A feasibility study

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Antineoplastic treatment with crizotinib during pregnancy: a case report

    Research output: Contribution to journalLetterResearchpeer-review

  4. Incorporating NTCP into Randomized Trials of Proton Versus Photon Therapy

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

Background: With 4DCT the risk of introducing positional systematic errors in lung cancer radiotherapy can be minimised. A common approach is to plan on the phase bin of the 4DCT best representing the tumour's time-weighted mean position also called the midventilation scan. However breathing irregularities can introduce uncertainties and potentially misrepresent both the tumour trajectory and the determination of the midventilation phase. In this study we evaluated the robustness of the midventilation approach in the presence of irregular breathing patterns. Methods: A LEGO Mindstorms® phantom with compact balls simulating lung tumours was constructed. The breathing curves loaded in the phantom were either acquired from a human volunteer or constructed with various magnitudes (ranging from 12 to 29mm) as well as various irregularities of motion pattern. Repeated 4DCT scans were performed while tumour trajectories were recorded with two motion tracking systems. Results: The time-weighted mean tumour position is accurately represented in 4DCT scans, even for irregular breathing patterns: the position presentation in the midventilation scan was always within in one standard deviation of the global position presentation (3mm and 2mm for regular and irregular breathing patterns, respectively). The displacement representation tended to be underestimated in 4DCT scans. Conclusion: The midventilation approach is robust even in the presence of breathing irregularity. The representation of the tumour trajectory in 4DCT scans is affected by breathing irregularity and the extent of tumour motion can be underestimated, which will affect the calculation of patient-individualised margins based on the 4DCT scan.

Original languageEnglish
JournalPhysica Medica
Volume30
Issue number1
Pages (from-to)69-75
Number of pages7
ISSN1120-1797
DOIs
Publication statusPublished - 1 Feb 2014

    Research areas

  • 4DCT, Breathing patterns, Midventilation

ID: 55866391