Efficacy of Implantable Cardioverter Defibrillator in Nonischemic Systolic Heart Failure According to Sex: Extended Follow-Up Study of the DANISH Trial

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Polygenic risk score for ACE-inhibitor-associated cough based on the discovery of new genetic loci

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Association between inflammatory markers and survival in comatose, resuscitated out-of-hospital cardiac arrest patients

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Long-term effects of cardiac rehabilitation after heart valve surgery - results from the randomised CopenHeartVR trial

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Symptoms reported in calls to emergency medical services within 24 hours prior to out-of-hospital cardiac arrest

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: Men and women may respond differently to certain therapies for heart failure with reduced ejection fraction, including implantable cardioverter defibrillators (ICD). In an extended follow-up study of the DANISH trial (Danish Study to Assess the Efficacy of ICDs in Patients With Non-Ischemic Systolic Heart Failure on Mortality), adding 4 years of additional follow-up, we examined the effect of ICD implantation according to sex.

METHODS: In the DANISH trial, 1116 patients with nonischemic systolic heart failure were randomized to receive an ICD (N=556) or usual clinical care (N=550). The primary outcome was all-cause mortality.

RESULTS: Of the 1116 patients randomized in the DANISH trial, 307 (27.5%) were women. During a median follow-up of 9.5 years, women had a lower associated rate of all-cause mortality (hazard ratio [HR], 0.60 [95% CI, 0.47-0.78]) cardiovascular death (HR, 0.62 [95% CI, 0.46-0.84]), nonsudden cardiovascular death (HR, 0.59 [95% CI, 0.42-0.85]), and a numerically lower rate of sudden cardiovascular death (HR, 0.70 [95% CI, 0.40-1.25]), compared with men. Compared with usual clinical care, ICD implantation did not reduce the rate of all-cause mortality, irrespective of sex (men, HR, 0.85 [95% CI, 0.69-1.06]; women, HR, 0.98 [95% CI, 0.64-1.50]; Pinteraction=0.51). In addition, sex did not modify the effect of ICD implantation on sudden cardiovascular death (men, HR, 0.57 [95% CI, 0.36-0.92]; women, HR, 0.68 [95% CI, 0.26-1.77]; Pinteraction=0.76).

CONCLUSIONS: In patients with nonischemic systolic heart failure, ICD implantation did not provide an overall survival benefit, but reduced sudden cardiovascular death, irrespective of sex.

REGISTRATION: URL: https://www.

CLINICALTRIALS: gov; Unique identifier: NCT00542945.

Original languageEnglish
JournalCirculation. Heart failure
Volume15
Issue number9
Pages (from-to)e009669
ISSN1941-3289
DOIs
Publication statusPublished - Sep 2022

    Research areas

  • Death, Sudden, Cardiac/etiology, Defibrillators, Implantable, Denmark, Female, Follow-Up Studies, Heart Failure, Systolic/etiology, Heart Failure/therapy, Humans, Male, Risk Factors, clinical trial, heart failure, mortality, defibrillator, implantable, women