Research
Print page Print page
Switch language
Rigshospitalet - a part of Copenhagen University Hospital
Published

Assessment of Predictors of Left Atrial Volume Response to a Transcatheter InterAtrial Shunt Device (from the REDUCE LAP-HF Trial)

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Causes of Mortality in the Marfan Syndrome(from a Nationwide Register Study)

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Long-Term Adverse Cardiac Outcomes in Patients With Sarcoidosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Risk of heart failure in type 2 diabetes complicated by incident ischaemic heart disease and end-stage renal disease

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Sacubitril/valsartan increases postprandial gastrin and cholecystokinin in plasma

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Favorable five-year outcomes for heart failure diagnosed in younger patients without severe comorbidity

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Effect of Heart Rate Reserve on Exercise Capacity in Patients Treated with a Continuous Left Ventricular Assist Device

    Research output: Contribution to journalJournal articleResearchpeer-review

  • REDUCE LAP-HF study investigators, and research staff
View graph of relations

In patients with heart failure and preserved or mildly reduced ejection fractions (EF ≥40%), implantation of an interatrial shunt device (IASD) resulted in heterogenous changes of the left atrial (LA) volume. Baseline characteristics that correlate with a favorable decrease in LA volume are unknown. We hypothesized that a larger ratio of left to right atrial volume at baseline would correlate strongly with LA volume decongestion following IASD implantation. Reduce Elevated LA Pressure in Patients With Heart Failure was a multicenter study of the safety and feasibility of IASD implantation. Sixty-four patients with EF ≥40% underwent device implantation along with baseline conventional echocardiograms, speckle tracking echocardiography, and resting and exercise hemodynamics. Higher LA compliance (-4.2%, p = 0.048) and right atrial reservoir strain (-0.8%, p = 0.005) were independently associated with a percent decrease in the systolic LA volume index from baseline to 6-months. In conclusion, greater LA volume reduction following IASD implantation is associated with higher baseline compliance of the left atrium and higher reservoir strain of the right atrium.

Original languageEnglish
JournalThe American journal of cardiology
Volume124
Issue number12
Pages (from-to)1912-1917
Number of pages6
ISSN0002-9149
DOIs
Publication statusPublished - 15 Dec 2019

ID: 59169511