Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Validation of an assessment tool for estimation of abdominal aortic aneurysm compression in diagnostic ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. First report on intraoperative vector flow imaging of the heart among patients with healthy and diseased aortic valves

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. In-vivo validation of fast spectral velocity estimation techniques

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Pressure Difference Estimation in Non-stenotic Carotid Bifurcation Phantoms Using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Highlights of the development in ultrasound during the last 70 years: A historical review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

Vis graf over relationer

A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice.

OriginalsprogEngelsk
TidsskriftUltrasonics
Vol/bind70
Sider (fra-til)136-46
Antal sider11
ISSN0041-624X
DOI
StatusUdgivet - aug. 2016

ID: 49612466