Vector Concentration used for Stenosis Assessment in the Carotid Artery before and after Carotid Stenting

Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

DOI

  1. History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  2. Pressure Difference Estimation in Carotid Bulbs using Vector Flow Imaging - A Phantom Study

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  3. Super-Resolution Ultrasound Imaging of Rat Kidneys before and after Ischemia-Reperfusion

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  4. Tissue Motion Estimation and Correction in Super Resolution Imaging

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  1. Postembolization Syndrome after Prostatic Artery Embolization: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Elastografie in der Brustbildgebung

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

Vis graf over relationer

Angiography of carotid stenosis is the preferred method for stenosis assessment, but the method is invasive and ionizing. The ultrasound technique Vector Flow Imaging (VFI) is proposed as a noninvasive and nonionizing alternative for stenosis assessment. Vessel stenosis and flow complexity are associated, and VFI can measure flow complexity with Vector Concentration (VC). VC goes towards 1 for laminar flow and 0 for complex flow. In this preliminary study, 5 patients treated with carotid stent for carotid artery stenosis were examined with VFI to evaluate if VC estimations were comparable with the corresponding digital substraction angiography (DSA) calculated stenosis degree percentage. VFI was obtained with a bk5000 ultrasound scanner and an 8L2 linear transducer with a frequency range from 2-8 MHz (BK Medical, Herlev, Denmark), while angiography data were obtained with Siemens Artis Q (Siemens, Erlangen, Germany). The flow in the stenosis was evaluated with VC as a mean over 100 frames with a frame rate of 30 Hz. VC of the stenotic carotid artery was low for all patients before stenting with a mean of 0.59 (SD:0.07), while mean VC increased to 0.97 (SD:0.02) after stenting (p=0.016). Mean DSA stenosis degree percentage was 82% (SD:9%) before stenting and was reduced to 11% (SD:6%) after stenting (p=0.001). Correlation coefficient between VC and DSA stenosis degree was strong 0.97. This is the first preliminary study that shows VFI can be used to evaluate stent treatment of carotid stenosis. The results indicate that VC is a useful parameter for flow complexity assessment, and that VC and stenosis degree are comparable for patients with carotid stenosis.

OriginalsprogEngelsk
TidsskriftIEEE International Ultrasonics Symposium, IUS
Sider (fra-til)348-351
Antal sider4
ISSN1948-5719
DOI
StatusUdgivet - 1 okt. 2019

ID: 59133611