Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Surgical Results and Complications of Cochlear Implantation in Far-Advanced Otosclerosis

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Reposition Chair Treatment Improves Subjective Outcomes in Refractory Benign Paroxysmal Positional Vertigo

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Audiovestibular Loss of Function Correlates in Vestibular Schwannomas

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Contemporary Molecular Biology of Sporadic Vestibular Schwannomas: A Systematic Review and Clinical Implications

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Cochlear MRI Signal Change Following Vestibular Schwannoma Resection Depends on Surgical Approach

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Association of SLC26A4 mutations, morphology, and hearing in pendred syndrome and NSEVA

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Reposition Chair Treatment Improves Subjective Outcomes in Refractory Benign Paroxysmal Positional Vertigo

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Benign paroksysmal positionel vertigo som komplikation ved hovedtraume

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Benign paroksysmal positionel vertigo som komplikation ved hovedtraume

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVE: To report surgical results and complications of cochlear implantation in patients with far-advanced otosclerosis (FAO).

MATERIALS AND METHODS: This was a retrospective chart review of surgical results in terms of electrode insertion as well as peri- and postoperative complications. Ten cochlear implantations (CIs) were performed in eight patients with FAO. A prior stapedotomy had been performed in all cases.

RESULTS: Full electrode insertion was achieved in nine of the 10 operations (90%) and partial insertion in one operation. An unintended opening of the vestibule during drilling was the only perioperative complication. Postoperative complications occurred as two cases of vertigo (one prolonged). No chorda tympani syndrome and no cases of facial nerve stimulation were noted.

CONCLUSION: Although based on a limited number of cases, we conclude that full electrode insertion can be achieved in almost all cases and that major complications are infrequent in CI in patients with FAO. Postoperative vertigo appears to be the most commonly occurring complication.

OriginalsprogEngelsk
TidsskriftJournal of Laryngology and Otology
Vol/bind13
Udgave nummer3
Sider (fra-til)304-307
Antal sider4
ISSN1308-7649
DOI
StatusUdgivet - dec. 2017

ID: 52573409