Rubidium-82 PET imaging is feasible in a rat myocardial infarction model

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. 123I-MIBG for detection of subacute doxorubicin-induced cardiotoxicity in patients with malignant lymphoma

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Stomach interference in 82Rb-PET myocardial perfusion imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Early risk stratification using Rubidium-82 positron emission tomography in STEMI patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Respiratory gating in cardiac PET: Effects of adenosine and dipyridamole

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Bone geometry, density, and microarchitecture in the distal radius and tibia in adults with Marfan Syndrome assessed by HR-pQCT

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Tumor cell MT1-MMP is dispensable for osteosarcoma tumor growth, bone degradation and lung metastasis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Limited diagnostic utility of Chromogranin A measurements in workup of neuroendocrine tumors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Background: Small-animal myocardial infarct models are frequently used in the assessment of new cardioprotective strategies. A validated quantification of perfusion using a non-cyclotron-dependent PET tracer would be of importance in monitoring response to therapy. We tested whether myocardial PET perfusion imaging is feasible with Rubidium-82 ( 82Rb) in a small-animal scanner using a rat myocardial infarct model. Methods: 18 Sprague-Dawley rats underwent permanent coronary artery ligation (infarct group), and 11 rats underwent ischemia-reperfusion (reperfusion group) procedure. 82Rb-PET and magnetic resonance imaging (MRI) were conducted before and after the intervention. Perfusion was compared to both left ventricle ejection fraction (LVEF) and infarct size assessed by MRI. Results: Follow-up global 82Rb-uptake correlated significantly with infarct size (infarct group: r = −0.81, P < 0.001 and reperfusion group: r = −0.61, P = 0.04). Only 82Rb-uptake in the infarct group correlated with LVEF. At follow-up, a higher segmental 82Rb-uptake in the infarct group was associated with better wall motion (β = 0.034, CI [0.028;0.039], P < 0.001, R 2 = 0.30), and inversely associated with scar transmurality (β = −2.4 [−2.6; −2.2], P < 0.001, R 2 = 0.59). The associations were similar for the reperfusion group. Conclusion: 82Rb-PET is feasible in small animal scanners despite the long positron range and enables fast and time-efficient myocardial perfusion imaging in rat models.

OriginalsprogEngelsk
TidsskriftJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
Vol/bind26
Udgave nummer3
Sider (fra-til)798-809
Antal sider12
ISSN1071-3581
DOI
StatusUdgivet - 2019

ID: 52703331