Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Pharmacokinetic Analysis of (64)Cu-ATSM Dynamic PET in Human Xenograft Tumors in Mice

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Limited diagnostic utility of Chromogranin A measurements in workup of neuroendocrine tumors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  3. Renal 123I-MIBG Uptake before and after Live-Donor Kidney Transplantation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Tumor cell MT1-MMP is dispensable for osteosarcoma tumor growth, bone degradation and lung metastasis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Limited diagnostic utility of Chromogranin A measurements in workup of neuroendocrine tumors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Changes in cardiac microvascular function in persons with type 2 diabetes in relation to kidney function

    Publikation: KonferencebidragKonferenceabstrakt til konferenceForskningpeer review

Vis graf over relationer

UNLABELLED: The aim of this study was to evaluate the feasibility to perform voxel-wise kinetic modeling on datasets obtained from tumor-bearing mice that underwent dynamic PET scans with (64)Cu-ATSM and extract useful physiological parameters.

METHODS: Tumor-bearing mice underwent 90-min dynamic PET scans with (64)Cu-ATSM and CT scans with contrast. Irreversible and reversible two-tissue compartment models were fitted to time activity curves (TACs) obtained from whole tumor volumes and compared using the Akaike information criterion (AIC). Based on voxel-wise pharmacokinetic analysis, parametric maps of model rate constants k₁, k₃ and Ki were generated and compared to (64)Cu-ATSM uptake.

RESULTS: Based on the AIC, an irreversible two-tissue compartment model was selected for voxel-wise pharmacokinetic analysis. Of the extracted parameters, k₁ (~perfusion) showed a strong correlation with early tracer uptake (mean spearman R = 0.88) 5 min post injection (pi). Moreover, positive relationships were found between late tracer uptake (90 min pi) and both k₃ and the net influx rate constant, Ki (mean spearman R = 0.56 and R = 0.86; respectively).

CONCLUSION: This study shows the feasibility to extract relevant parameters from voxel-wise pharmacokinetic analysis to be used for preclinical validation of (64)Cu-ATSM as a hypoxia-specific PET tracer.