Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Mechanical and vasomotor properties of piglet isolated middle cerebral artery

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Pharmacokinetic variability of beta-adrenergic blocking agents used in cardiology

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Clinical trial allocation in multinational pharmaceutical companies - a qualitative study on influential factors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Translational value of mechanical and vasomotor properties of mouse isolated mesenteric resistance-sized arteries

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Cerebral oxygenation and blood flow in normal term infants at rest measured by a hybrid near-infrared device (BabyLux)

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Neurodevelopmental disorder in children believed to have isolated mild ventriculomegaly prenatally

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Hybrid PET/MRI imaging in healthy unsedated newborn infants with quantitative rCBF measurements using 15O-water PET

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Infections seem to be more frequent before onset of pediatric multiple sclerosis: A Danish nationwide nested case-control study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Piglets are often used as experimental models for studying cerebrovascular responses in newborn infants. However, the mechanical characteristics of piglets' middle cerebral arteries (MCA) are not well characterized. Additionally, the vessels' response to dopamine, the most commonly used vasopressor in newborns, is not characterized in piglets' MCA. Finally, the influence of preterm birth on the dopamine response is not known. The aim of this current was to compare by wire myography the active and passive mechanical characteristics and dopamine concentration-response relations of MCAs isolated from preterm and term newborn piglets. Second-order branches of the MCA with a diameter <400 μm were chosen for study. The active and passive mechanical properties were comparable between vessels from six preterm (90% gestation, nsegments = 11) and nine term (nsegments = 22) newborn piglets. The response to increasing concentrations of dopamine was biphasic, starting with vasodilation in the 1 nmol/L-0.3 μmol/L concentration range followed by vasoconstriction at higher concentrations. The response was very similar between the two groups. In conclusion, the mechanical properties of the MCA as well as the response to dopamine were comparable between term and 90% gestation preterm piglets.

OriginalsprogEngelsk
TidsskriftPharmacology Research & Perspectives
Vol/bind5
Udgave nummer1
Sider (fra-til)e00279
ISSN2052-1707
DOI
StatusUdgivet - feb. 2017

ID: 52372231