Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Learning Curves and Competences of Vascular Trainees Performing Open Aortic Repair in a Simulation-Based Environment

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. In Situ Vein Bypass Is Superior to Endovascular Treatment of Femoropopliteal Lesions in Chronic Limb-Threatening Ischemia

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Contrast-Enhanced Ultrasound in Vascular Surgery: Review and Update

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  1. Three-dimensional ultrasound is a reliable alternative in endovascular aortic repair surveillance

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Validation of an assessment tool for estimation of abdominal aortic aneurysm compression in diagnostic ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Effect of revascularization on lower extremity muscle function in combined type 2 diabetes and critical limb threatening ischemia

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Low Risk of Neurological Recurrence while Awaiting Carotid Endarterectomy: Results From a Danish Multicentre Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Take the Direct Route When Evaluating Training Effects in Lower Extremity Arterial Disease: Use Near Infrared Spectroscopy!

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: The aim of this study was to analyze learning curves and competency gains of novice vascular trainees when performing open aortic repair in a simulation-based environment.

METHODS: This was a prospective study of 16 vascular trainees performing infrarenal open aortic repair on an inanimate abdominal aortic aneurysm simulator with pulsatile pressure and flow. Each participant performed 4 procedures as a primary surgeon while getting structured feedback by a supervising experienced vascular surgeon. All sessions were video recorded and were anonymously and independently assessed by 3 rater-trained experts on an online platform using the newly validated open abdominal aortic aneurysm repair of technical expertise assessment tool. All supervisor interferences and procedure time was noted.

RESULTS: Reliability between raters was excellent (intraclass correlation coefficient = 0.92). Participants' mean scores almost doubled during the course between the first (13.4, 95% confidence interval [CI], 6.8-20) and fourth session (29.8, 95% CI, 26.3-33.3) with a mean difference of 14.6 (P < 0.001). Supervisor interference also decreased significantly from mean 3.0 (95% CI, 1.5-3.6) in the first to 0.7 (95% CI, 0.4-1.0) in the fourth session (P = 0.004). Procedure time decreased with a mean of 24 minutes: from 81 min (95% CI, 71.8-90.3) to 57 min (95% CI, 51.1-63.2, P < 0.001). There was a significant negative correlation between procedure time and the Open Abdominal Aortic Aneurysm Repair of Technical Expertise score (Pearson's r = -0.72, P < 0.01). Only half of the participants passed the pass/fail score of 27.7 points during the course.

CONCLUSIONS: Novice vascular trainees achieve skills and competencies in open aortic repair in a simulated setting with dedicated supervision and feedback and can become ready for supervised surgery on real patients. Learning rates are individual, and it is important to construct training programs with emphasis on proficiency and not merely attending a course.