Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

In-vivo validation of fast spectral velocity estimation techniques

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Validation of an assessment tool for estimation of abdominal aortic aneurysm compression in diagnostic ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. First report on intraoperative vector flow imaging of the heart among patients with healthy and diseased aortic valves

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Pressure Difference Estimation in Non-stenotic Carotid Bifurcation Phantoms Using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Evaluation of 2D super-resolution ultrasound imaging of the rat renal vasculature using ex vivo micro-computed tomography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Highlights of the development in ultrasound during the last 70 years: A historical review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

Vis graf over relationer
Spectrograms in medical ultrasound are usually estimated with Welch's method (WM). WM is dependent on an observation window (OW) of up to 256 emissions per estimate to achieve sufficient spectral resolution and contrast. Two adaptive filterbank methods have been suggested to reduce the OW: Blood spectral Power Capon (BPC) and the Blood Amplitude and Phase EStimation method (BAPES). Ten volunteers were scanned over the carotid artery. From each data set, 28 spectrograms were produced by combining four approaches (WM with a Hanning window (W.HAN), WM with a boxcar window (W.BOX), BPC and BAPES) and seven OWs (128, 64, 32, 16, 8, 4, 2). The full-width-at-half-maximum (FWHM) and the ratio between main and side-lobe levels were calculated at end-diastole for each spectrogram. Furthermore, all 280 spectrograms were randomized and presented to nine radiologists for visual evaluation: useful/not useful. BAPES and BPC compared to WM had better resolution (lower FWHM) for all OW0.05) at OW 128 and 64, while W.BOX scored less (p
OriginalsprogEngelsk
TidsskriftUltrasonics
Vol/bind50
Udgave nummer1
Sider (fra-til)52-9
Antal sider8
ISSN0041-624X
DOI
StatusUdgivet - 1 jan. 2010

ID: 31044568