Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Detection of atrial fibrillation with implantable loop recorders in horses

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Hjertestop hos en patient med langt QT-syndrom i androgendeprivationsterapi

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Sudden unexpected death in epilepsy in persons younger than 50 years: A retrospective nationwide cohort study in Denmark

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Temporal trends and sex differences in sudden cardiac death in the Copenhagen City Heart Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Witnessed and unwitnessed sudden cardiac death: a nationwide study of persons aged 1-35 years

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Cardiac arrhythmias in patients hospitalized with COVID-19: The ACOVID study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • Rikke Buhl
  • Eva M Hesselkilde
  • Helena Carstensen
  • Merle F Fenner
  • Thomas Jespersen
  • Jacob Tfelt-Hansen
  • Stefan Michael Sattler
Vis graf over relationer

BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients.

OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time.

STUDY DESIGN: Experimental study.

METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left-6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R- and T-wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2-month period was compared with selected Holter ECG recordings.

RESULTS: All three positions had stable R- and T-wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left-6 showed significantly higher R- and T-wave amplitudes compared with the other positions. During submaximal exercise only the Left-6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts.

MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied.

CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses.

OriginalsprogEngelsk
TidsskriftEquine Veterinary Journal
Vol/bind53
Udgave nummer2
Sider (fra-til)397-403
Antal sider7
ISSN2042-3306
DOI
StatusUdgivet - mar. 2021

Bibliografisk note

© 2020 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

ID: 62373475