Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Design of Infusion Schemes for Neuroreceptor Imaging: Application to [(11)C]Flumazenil-PET Steady-State Study

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Expression of C4.4A in an In Vitro Human Tissue-Engineered Skin Model

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Self-Rated Health as a Predictor of Death after Two Years: The Importance of Physical and Mental Wellbeing Postintensive Care

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Is the Experience of Thermal Pain Genetics Dependent?

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Diagnostic yield of high-density versus low-density EEG: The effect of spatial sampling, timing and duration of recording

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Optimization of preprocessing strategies in Positron Emission Tomography (PET) neuroimaging: A [11C]DASB PET study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Transcriptome analysis in patients with temporal lobe epilepsy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Development and Evaluation of Two Potential 5-HT7 Receptor PET Tracers: [18F]ENL09 and [18F]ENL10

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Association Between Sumatriptan Treatment During a Migraine Attack and Central 5-HT1B Receptor Binding

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

This study aims at developing a simulation system that predicts the optimal study design for attaining tracer steady-state conditions in brain and blood rapidly. Tracer kinetics was determined from bolus studies and used to construct the system. Subsequently, the system was used to design inputs for bolus infusion (BI) or programmed infusion (PI) experiments. Steady-state quantitative measurements can be made with one short scan and venous blood samples. The GABAA receptor ligand [(11)C]Flumazenil (FMZ) was chosen for this purpose, as it lacks a suitable reference region. Methods. Five bolus [(11)C]FMZ-PET scans were conducted, based on which population-based PI and BI schemes were designed and tested in five additional healthy subjects. The design of a PI was assisted by an offline feedback controller. Results. The system could reproduce the measurements in blood and brain. With PI, [(11)C]FMZ steady state was attained within 40 min, which was 8 min earlier than the optimal BI (B/I ratio = 55 min). Conclusions. The system can design both BI and PI schemes to attain steady state rapidly. For example, subjects can be [(11)C]FMZ-PET scanned after 40 min of tracer infusion for 40 min with venous sampling and a straight-forward quantification. This simulation toolbox is available for other PET-tracers.

OriginalsprogEngelsk
Artikelnummer9132840
TidsskriftBioMed Research International
Vol/bind2016
Antal sider8
DOI
StatusUdgivet - 2016

ID: 46492728