Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Deep learning for Dixon MRI-based attenuation correction in PET/MRI of head and neck cancer patients

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. A Nordic survey of CT doses in hybrid PET/CT and SPECT/CT examinations

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. [(123)I]FP-CIT ENC-DAT normal database: the impact of the reconstruction and quantification methods

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Cross-calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long-term stability and reproducibility

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Causes and Risk Factors of Pediatric Spontaneous Intracranial Hemorrhage-A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. A convolutional neural network for total tumor segmentation in [64Cu]Cu-DOTATATE PET/CT of patients with neuroendocrine neoplasms

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Multi-parametric PET/MRI for enhanced tumor characterization of patients with cervical cancer

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: Quantitative whole-body PET/MRI relies on accurate patient-specific MRI-based attenuation correction (AC) of PET, which is a non-trivial challenge, especially for the anatomically complex head and neck region. We used a deep learning model developed for dose planning in radiation oncology to derive MRI-based attenuation maps of head and neck cancer patients and evaluated its performance on PET AC.

METHODS: Eleven head and neck cancer patients, referred for radiotherapy, underwent CT followed by PET/MRI with acquisition of Dixon MRI. Both scans were performed in radiotherapy position. PET AC was performed with three different patient-specific attenuation maps derived from: (1) Dixon MRI using a deep learning network (PETDeep). (2) Dixon MRI using the vendor-provided atlas-based method (PETAtlas). (3) CT, serving as reference (PETCT). We analyzed the effect of the MRI-based AC methods on PET quantification by assessing the average voxelwise error within the entire body, and the error as a function of distance to bone/air. The error in mean uptake within anatomical regions of interest and the tumor was also assessed.

RESULTS: The average (± standard deviation) PET voxel error was 0.0 ± 11.4% for PETDeep and -1.3 ± 21.8% for PETAtlas. The error in mean PET uptake in bone/air was much lower for PETDeep (-4%/12%) than for PETAtlas (-15%/84%) and PETDeep also demonstrated a more rapidly decreasing error with distance to bone/air affecting only the immediate surroundings (less than 1 cm). The regions with the largest error in mean uptake were those containing bone (mandible) and air (larynx) for both methods, and the error in tumor mean uptake was -0.6 ± 2.0% for PETDeep and -3.5 ± 4.6% for PETAtlas.

CONCLUSION: The deep learning network for deriving MRI-based attenuation maps of head and neck cancer patients demonstrated accurate AC and exceeded the performance of the vendor-provided atlas-based method both overall, on a lesion-level, and in vicinity of challenging regions such as bone and air.