Blood-brain barrier permeability measured using dynamic contrast-enhanced magnetic resonance imaging: a validation study

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Regulation of plasma volume in male lowlanders during 4 days of exposure to hypobaric hypoxia equivalent to 3500 m altitude

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Heterogeneity in subcellular muscle glycogen utilisation during exercise impacts endurance capacity in men

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. KATP channels modulate cerebral blood flow and oxygen delivery during isocapnic hypoxia in humans

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Human brain blood flow and metabolism during isocapnic hyperoxia: the role of reactive oxygen species

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Lower body negative pressure to safely reduce intracranial pressure

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Volume of hippocampal subregions and clinical improvement following electroconvulsive therapy in patients with depression

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Intradural artery dilation during experimentally induced migraine attacks

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Feasibility of Glutamate and GABA Detection in Pons and Thalamus at 3T and 7T by Proton Magnetic Resonance Spectroscopy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Physiological responses of human skeletal muscle to acute blood flow restricted exercise assessed by multimodal MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

KEY POINTS: The blood-brain barrier (BBB) is an important and dynamic structure which contributes to homeostasis in the central nervous system. BBB permeability changes occur in health and disease but measurement of BBB permeability in humans is not straightforward. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to model the movement of gadolinium contrast into the brain, expressed as the influx constant Ki . Here evidence is provided that Ki as measured by DCE-MRI behaves as expected for a marker of overall BBB leakage. These results support the use of DCE-MRI for in vivo studies of human BBB permeability in health and disease.

ABSTRACT: Blood-brain barrier (BBB) leakage can be measured using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as the influx constant Ki . To validate this method we compared measured Ki with biological expectations, namely (1) higher Ki in healthy individual grey matter (GM) versus white matter (WM), (2) GM/WM cerebral blood volume (CBV) ratio close to the histologically established GM/WM vascular density ratio, (3) higher Ki in visibly enhancing multiple sclerosis (MS) lesions versus MS normal appearing white matter (NAWM), and (4) higher Ki in MS NAWM versus healthy individual NAWM. We recruited 13 healthy individuals and 12 patients with MS and performed whole-brain 3D DCE-MRI at 3 T. Ki and CBV were calculated using Patlak modelling for manual regions of interest (ROI) and segmented tissue masks. Ki was higher in control GM versus WM (P = 0.001). CBV was higher in GM versus WM (P = 0.005, mean ratio 1.9). Ki was higher in visibly enhancing MS lesions versus MS NAWM (P = 0.002), and in MS NAWM versus controls (P = 0.014). Bland-Altman analysis showed no significant difference between ROI and segmentation methods (P = 0.638) and an intra-class correlation coefficient showed moderate single measure consistency (0.610). Ki behaves as expected for a compound marker of permeability and surface area. The GM/WM CBV ratio measured by this technique is in agreement with the literature. This adds evidence to the validity of Ki measured by DCE-MRI as a marker of overall BBB leakage.

OriginalsprogEngelsk
TidsskriftThe Journal of physiology
Vol/bind597
Udgave nummer3
Sider (fra-til)699-709
Antal sider11
ISSN0022-3751
DOI
StatusUdgivet - feb. 2019