Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
E-pub ahead of print

Automated artificial intelligence-based system for clinical follow-up of patients with age-related macular degeneration

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Proteomic analysis of vitreous humour of eyes with diabetic macular oedema: a systematic review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Ophthalmic nepafenac use in the Netherlands and Denmark

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Human parallels to experimental myopia? A literature review on visual deprivation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Pretraining of basic skills on a virtual reality vitreoretinal simulator: A waste of time

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Prevalence and severity of diabetic retinopathy in pregnant women with diabetes-time to individualize photo screening frequency

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Quantifying surgical skill in macular surgery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Intracranial pressure and optic disc changes in a rat model of obstructive hydrocephalus

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

PURPOSE: In this study, we investigate the potential of a novel artificial intelligence-based system for autonomous follow-up of patients treated for neovascular age-related macular degeneration (AMD).

METHODS: A temporal deep learning model was trained on a data set of 84 489 optical coherence tomography scans from AMD patients to recognize disease activity, and its performance was compared with a published non-temporal model trained on the same data (Acta Ophthalmol, 2021). An autonomous follow-up system was created by augmenting the AI model with deterministic logic to suggest treatment according to the observe-and-plan regimen. To validate the AI-based system, a data set comprising clinical decisions and imaging data from 200 follow-up consultations was collected prospectively. In each case, both the autonomous AI decision and original clinical decision were compared with an expert panel consensus.

RESULTS: The temporal AI model proved superior at detecting disease activity compared with the model without temporal input (area under the curve 0.900 (95% CI 0.894-0.906) and 0.857 (95% CI 0.846-0.867) respectively). The AI-based follow-up system could make an autonomous decision in 73% of the cases, 91.8% of which were in agreement with expert consensus. This was on par with the 87.7% agreement rate between decisions made in the clinic and expert consensus (p = 0.33).

CONCLUSIONS: The proposed autonomous follow-up system was shown to be safe and compliant with expert consensus on par with clinical practice. The system could in the future ease the pressure on public ophthalmology services from an increasing number of AMD patients.

OriginalsprogEngelsk
TidsskriftActa Ophthalmologica (Online)
ISSN1755-3768
DOI
StatusE-pub ahead of print - 2022

Bibliografisk note

© 2022 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

ID: 78192402