Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

Assessment of EVAR Competence: Validity of a Novel Rating Scale (EVARATE) in a Simulated Setting

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Endovascular Treatment of Chronic and Acute on Chronic Mesenteric Ischaemia: Results From a National Cohort of 245 Cases

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Simulation Based Training and Assessment in Open Vascular Surgery: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  3. Contemporary Treatment of Popliteal Artery Aneurysms in 14 Countries: A Vascunet Report

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Dual-energy CT

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Endovascular Treatment of Chronic and Acute on Chronic Mesenteric Ischaemia: Results From a National Cohort of 245 Cases

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Learning Curves and Competences of Vascular Trainees Performing Open Aortic Repair in a Simulation-Based Environment

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVES: The aims of this study were to investigate the validity evidence for a novel procedure specific assessment tool of competence in endovascular aortic repair (EVAR) and to establish a pass/fail level for the assessment.

METHODS: Computed tomography angiography data of a 55 mm in diameter infrarenal aortic aneurysm was implemented into an endovascular simulator. Twenty-three physicians with varying EVAR experiences were video-recorded when performing a standard EVAR procedure on the simulator. Two experienced EVAR operators assessed the participants using the novel rating scale, "EndoVascular Aortic Repair Assessment of Technical Expertise" (EVARATE). Validity was studied according to the framework endorsed by the American Educational Research Association.

RESULTS: The EVARATE scale had a high internal consistency (Cronbach's alpha = .90). The inter-rater reliability was acceptable (Intraclass Correlation Coefficient = .68, p = .005). Specific EVAR experience correlated significantly with the EVARATE score (Spearman's rho = .62, p = .002), but general endovascular experience did not. Consequence analysis showed that the EVARATE assessment could distinguish novices from intermediates (p < .01) and from experts (p < .001). A pass/fail score was determined using the contrasting groups' method.

CONCLUSION: This paper presents the initial validity evidence for a novel procedure specific assessment tool, EVARATE, for operator competence in endovascular aortic repair investigated in a simulated setting. The assessment tool can be used to provide structured formative feedback to trainees.

OriginalsprogEngelsk
TidsskriftEuropean journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
Vol/bind56
Udgave nummer1
Sider (fra-til)137-144
Antal sider8
ISSN1078-5884
DOI
StatusUdgivet - jul. 2018