Forskning
Udskriv Udskriv
Switch language
Rigshospitalet - en del af Københavns Universitetshospital
Udgivet

A new wide-diameter bone-anchored hearing implant-prospective 1-year data on complications, implant stability, and survival

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Cochlear MRI Signal Change Following Vestibular Schwannoma Resection Depends on Surgical Approach

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Superior Canal Dehiscence Surgery Outcomes Following Failed Round Window Surgery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. The Natural History of Hearing Loss in Pendred Syndrome and Non-Syndromic Enlarged Vestibular Aqueduct

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Utility of Postoperative Magnetic Resonance Imaging in Patients Who Fail Superior Canal Dehiscence Surgery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Cochlear MRI Signal Change Following Vestibular Schwannoma Resection Depends on Surgical Approach

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Association of SLC26A4 mutations, morphology, and hearing in pendred syndrome and NSEVA

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Knogleforankrede høreapparater og aktive mellemøreimplantater

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVE: To investigate a new wide bone-anchored hearing implant considering initial stability, stability over time, implant loss, and skin reaction.

STUDY DESIGN: Consecutive, prospective case series.

SETTING: Tertiary referral center.

PATIENTS: Twenty adult patients were enrolled. All operations were 1-stage, single-incision technique with subcutaneous reduction.

INTERVENTION(S): Measurement of implant stability.

MAIN OUTCOME MEASURE(S): Implant stability quotient (ISQ) values were recorded using resonance frequency analysis at the time of implantation and at 10 days, 6 weeks, 6 months, and 1 year after surgery. Skin and soft tissue reactions according to Holgers grading system.

RESULTS: Implant stability quotient measurements revealed a significant increase in ISQ during the first 10 days after operation, and the ISQ values continued to rise throughout the 1-year observation period. No implants were lost. Skin and soft tissue reactions were rare and minor, as no reaction was seen in 93% of the follow-up examinations and no grade 4 reactions occurred.

CONCLUSION: The new wide implant showed good stability at surgery. Osseointegration was fast, and implant stability increased throughout the 1-year observation period. No implants were lost. Skin and soft tissue reactions were rare and minor.