Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Thromboembolic and bleeding complications following primary total knee arthroplasty: a Danish nationwide cohort study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Ten-year follow-up of stemmed hemiarthroplasty for acute proximal humeral fractures

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Is tranexamic acid use in patients with a hip fracture safe?

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. High-dose steroids in high pain responders undergoing total knee arthroplasty: a randomised double-blind trial

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Postoperative complications: an observational study of trends in the United States from 2012 to 2018

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Treatment of osteoarthritis with autologous, micro-fragmented adipose tissue: a study protocol for a randomized controlled trial

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

AIMS: The objective of this five-year prospective, blinded, randomised controlled trial (RCT) was to compare femoral head penetration into a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner with penetration into a medium cross-linked polyethylene control liner using radiostereometric analysis.

PATIENTS AND METHODS: Patients scheduled for total hip arthroplasty (THA) were randomised to receive either the study E1 (32 patients) or the control ArComXL polyethylene (35 patients). The median age (range) of the overall cohort was 66 years (40 to 76).

RESULTS: The five-year median (interquartile range) proximal femoral head penetration into the E1 was -0.05 mm (-0.13 to -0.02) and 0.07 mm (-0.03 to 0.16) for ArComXL. At three and five years, the penetration was significantly greater in the ArComXL group compared with the E1 group (p = 0.029 and p = 0.019, respectively). All patient-reported outcomes (PROs) improved significantly from the pre-operative interval compared with those at one year, and remained favourable at five years. There were no differences between the two groups at any interval.

CONCLUSION: The five-year results showed that E1 polyethylene does not wear more than the control, ArComXL. This is the longest-term RCT comparing the wear performance and clinical outcome of vitamin E diffused HXLPE with a previous generation of medium cross-linked polyethylene. Cite this article: Bone Joint J 2017;99-B:577-84.