Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Validation of the System One RemStar Auto A-Flex for Obstructive Sleep Apnea Treatment and Detection of Residual Apnea-Hypopnea Index: A European Randomized Trial

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Normal Morning MCH Levels and No Association with REM or NREM Sleep Parameters in Narcolepsy Type 1 and Type 2

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Effect of biological therapy on the risk of sleep apnea in patients with psoriasis

    Research output: Contribution to journalLetterResearchpeer-review

  3. Psoriasis and Sleep Apnea: A Danish Nationwide Cohort Study

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Large genome-wide association study identifies three novel risk variants for restless legs syndrome

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. A review of sleep research in patients with spinal cord injury

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Pupillary light responses in type 1 and type 2 diabetics with and without retinopathy

    Research output: Contribution to journalJournal articleResearchpeer-review

  • Frédéric Gagnadoux
  • Dirk Pevernagie
  • Poul Jennum
  • Nina Lon
  • Corinne Loiodice
  • Renaud Tamisier
  • Petra van Mierlo
  • Wojciech Trzepizur
  • Martina Neddermann
  • Annika Machleit
  • Jeffrey Jasko
  • Jean Louis Pépin
View graph of relations

STUDY OBJECTIVES: Autotitrating continuous positive airway pressure (CPAP) devices adjust pressure in response to changes in airflow and are an alternative to attended in-laboratory titration polysomnography (PSG) to determine optimal pressure levels. The aim of this study was to compare the performance of the System One RemStar Auto A-Flex (Philips Respironics, Murrysville, PA, USA) automatically adjusted positive airway pressure (APAP) mode to manually titrated, fixed pressure CPAP and to validate the device's breathing event detection capabilities against attended in-laboratory PSG.

METHODS: Sixty-one patients investigated in five centers for moderate to severe obstructive sleep apnea between May 2012 and June 2013 were invited to participate. Participants underwent two full-night attended polysomnograms in random order with manually titrated, fixed pressure CPAP versus APAP.

RESULTS: Fifty-three participants with a mean apnea-hypopnea index (AHI) of 45.9 ± 23 completed two sleep studies and were included in the analysis. There were significant but not clinically relevant differences between APAP and CPAP respectively: Apnea index [1.0 (2.8 ± .8), median (mean ± standard deviation)] versus [1.8 (5.3±11.5)], p = 0.004; percentage of N1 sleep [12.3 (15.9 ± .5)] versus [14.3 (18.9 ± 12.7)], p = 0.028. AHI values differed between PSG [2.8 (5.5. ± 9.3)] and device [3.7 (6.0 ± 8.6)], p = 0.003). Regarding residual events detection, intraclass correlation coefficients for AHI were strong (0.956, p < 0.001) and the area under the curve was 0.988 (AHI cut-off value of 10).

CONCLUSIONS: The new APAP modality was effective and residual apnea-hypopnea indices calculated by the device strongly correlated to those assessed by PSG.

Original languageEnglish
JournalJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine
Volume13
Issue number2
Pages (from-to)283-290
ISSN1550-9389
Publication statusPublished - 2017