Skip to main navigation Skip to search Skip to main content

Tuned exchange imaging: Can the filter exchange imaging pulse sequence be adapted for applications with thin slices and restricted diffusion?

Samo Lasič, Arthur Chakwizira, Henrik Lundell, Carl-Fredrik Westin, Markus Nilsson

4 Citations (Scopus)

Abstract

Filter exchange imaging (FEXI) is a double diffusion-encoding (DDE) sequence that is specifically sensitive to exchange between sites with different apparent diffusivities. FEXI uses a diffusion-encoding filtering block followed by a detection block at varying mixing times to map the exchange rate. Long mixing times enhance the sensitivity to exchange, but they pose challenges for imaging applications that require a stimulated echo sequence with crusher gradients. Thin imaging slices require strong crushers, which can introduce significant diffusion weighting and bias exchange rate estimates. Here, we treat the crushers as an additional encoding block and consider FEXI as a triple diffusion-encoding sequence. This allows the bias to be corrected in the case of multi-Gaussian diffusion, but not easily in the presence of restricted diffusion. Our approach addresses challenges in the presence of restricted diffusion and relies on the ability to independently gauge sensitivities to exchange and restricted diffusion for arbitrary gradient waveforms. It follows two principles: (i) the effects of crushers are included in the forward model using signal cumulant expansion; and (ii) timing parameters of diffusion gradients in filter and detection blocks are adjusted to maintain the same level of restriction encoding regardless of the mixing time. This results in the tuned exchange imaging (TEXI) protocol. The accuracy of exchange mapping with TEXI was assessed through Monte Carlo simulations in spheres of identical sizes and gamma-distributed sizes, and in parallel hexagonally packed cylinders. The simulations demonstrate that TEXI provides consistent exchange rates regardless of slice thickness and restriction size, even with strong crushers. However, the accuracy depends on b-values, mixing times, and restriction geometry. The constraints and limitations of TEXI are discussed, including suggestions for protocol adaptations. Further studies are needed to optimize the precision of TEXI and assess the approach experimentally in realistic, heterogeneous substrates.

Original languageEnglish
Article numbere5208
JournalNMR in Biomedicine
Volume37
Issue number11
Pages (from-to)1-22
Number of pages22
ISSN0952-3480
DOIs
Publication statusPublished - Nov 2024

Keywords

  • Algorithms
  • Computer Simulation
  • Diffusion
  • Diffusion Magnetic Resonance Imaging
  • Phantoms, Imaging
  • Signal Processing, Computer-Assisted
  • restricted diffusion
  • filter exchange imaging
  • time-dependent diffusion
  • cumulant expansion
  • diffusion MRI
  • exchange
  • diffusion spectrum
  • encoding power spectrum

Fingerprint

Dive into the research topics of 'Tuned exchange imaging: Can the filter exchange imaging pulse sequence be adapted for applications with thin slices and restricted diffusion?'. Together they form a unique fingerprint.

Cite this