Transcatheter Aortic Valve-in-Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis

  • Clare Rayner*
  • , Sarang Paleri
  • , Arri Satpal
  • , Daijiro Tomii
  • , Thomas Pilgrim
  • , Pablo Codner
  • , Ran Kornowski
  • , Antonio Mangieri
  • , Francesco Tartaglia
  • , Victor Mauri
  • , Ole De Backer
  • , Yusuke Kobari
  • , Luis Nombela-Franco
  • , Alfonso Ielasi
  • , Mariama Akodad
  • , Ruxandra Sava
  • , Tiffany Patterson
  • , Simon Redwood
  • , Heath Adams
  • *Corresponding author for this work

Abstract

Background: Valve-in-valve aortic valve implantation (ViV-TAVI) offers a less invasive treatment option for patients with a failing surgical bioprosthesis, avoiding the need for redo surgery. ViV-TAVI within a stentless bioprosthetic valve poses unique technical challenges. We report an international, multicentre experience evaluating procedural and clinical outcomes for patients undergoing ViV-TAVI for failed stentless bioprosthetic aortic valves. Aims: To evaluate the procedural feasibility, safety, and clinical outcomes of ViV-TAVI performed for failed stentless bioprosthetic aortic valves in an international, multicentre cohort. Methods: We retrospectively analysed 65 patients who underwent ViV-TAVI for stentless valve failure between 2010 and 2024. Outcome endpoints were based on the Valve Academic Research Consortium 3 (VARC-3) criteria. Results: Sixty-five patients (mean age 78.8 ± 10.2 years; 66.1% male; mean STS-PROM 6.9 ± 4.7) were included. The mean interval between surgical valve implantation and failure was 12.9 ± 4.1 years, with regurgitation the predominant mechanism of valve dysfunction (52.3%). Procedural success was achieved in 92.3%. 17 patients (26.2%) had upfront coronary protection. Despite this, six patients required unplanned percutaneous coronary intervention (PCI) for coronary obstruction. The 30-day and 1-year mortality rate was 0% and 8% respectively. Conclusions: ViV-TAVI was an effective intervention for patients with failing stentless bioprosthetic valves, with high procedural success rates despite unique technical challenges. Careful preprocedural imaging, planning, and implementation of coronary protection strategies are critical for optimal patient outcomes.

Original languageEnglish
JournalCatheterization and Cardiovascular Interventions
Volume107
Issue number2
Pages (from-to)647-654
Number of pages8
ISSN1522-1946
DOIs
Publication statusPublished - Feb 2026

Keywords

  • aortic stenosis
  • coronary obstruction
  • stentless bioprosthesis
  • TAVI
  • valve-in-valve
  • Humans
  • Heart Valve Prosthesis
  • Risk Factors
  • Bioprosthesis
  • Male
  • Transcatheter Aortic Valve Replacement/adverse effects
  • Treatment Outcome
  • Prosthesis Design
  • Feasibility Studies
  • Aortic Valve Stenosis/diagnostic imaging
  • Prosthesis Failure
  • Time Factors
  • Heart Valve Prosthesis Implantation/adverse effects
  • Aged, 80 and over
  • Female
  • Aortic Valve/surgery
  • Retrospective Studies
  • Aged
  • Aortic Valve Insufficiency/diagnostic imaging

Fingerprint

Dive into the research topics of 'Transcatheter Aortic Valve-in-Valve Implantation for Failing Stentless Bioprosthetic Aortic Valves: An International Multicentre Retrospective Analysis'. Together they form a unique fingerprint.