Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Tissue Motion Estimation and Correction in Super Resolution Imaging

Research output: Contribution to journalConference articleResearchpeer-review

  1. History and Latest Advances in Flow Estimation Technology: From 1-D in 2-D to 3-D in 4-D

    Research output: Contribution to journalConference articleResearchpeer-review

  2. Pressure Difference Estimation in Carotid Bulbs using Vector Flow Imaging - A Phantom Study

    Research output: Contribution to journalConference articleResearchpeer-review

  3. Super-Resolution Ultrasound Imaging of Rat Kidneys before and after Ischemia-Reperfusion

    Research output: Contribution to journalConference articleResearchpeer-review

  4. Vector Concentration used for Stenosis Assessment in the Carotid Artery before and after Carotid Stenting

    Research output: Contribution to journalConference articleResearchpeer-review

  1. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review

    Research output: Contribution to journalReviewResearchpeer-review

  2. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Postembolization Syndrome after Prostatic Artery Embolization: A Systematic Review

    Research output: Contribution to journalReviewResearchpeer-review

  4. Carotid Stenosis Assessment with Vector Concentration before and after Stenting

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

Super resolution imaging (SRI) can attain resolutions in the 10-20 μm range to visualize capillary circulation. It requires completely stationary interrogated tissue during the 3- to 10-minute acquisition, which is not obtainable for live animals apart from in the brain. All other organs move due to respiration, heart pulsation, and muscle activity. SRI can, thus, only be obtained with proper compensation for these motions. A method for full 2D tissue motion estimation is suggested, and it is shown how this motion compensation can restore SRI of small vessels in a rat kidney. A BK 5000 scanner was used with a X18L5 transducer (BK Medical). B-mode and contrast pulse sequence images were acquired with an MI of 0.2 at a 54 Hz frame rate for 10 min. The left kidney of a male Sprague-Dawley rat was scanned during laparotomy. A 1:10 diluted SonoVue contrast agent (Bracco) was injected through a jugular vein catheter at 100 μl/min. Envelope B-mode data were used for 2D tissue speckle tracking with sub-pixel precision in a central region of the kidney for axial and lateral motion estimation relative to a reference frame. The three motion components from the rat's forced ventilation, heart beat, and residual muscular motion were isolated by using the harmonics of the different motion frequencies (breathing 71 bpm, heart 280-350 bpm, residual: other frequencies). The precision of the motion was found by aligning signals across cycles and thereby estimating the mean standard deviation. The motion signal was used for compensating the position of the individual bubble locations back to that of the reference frame to remove motion. Estimated peak motions were: Heart: Axial: 1.2±0:079μm, Lateral: 7±0.99μm, Breathing Ax: 8±0.22μm, Lat: 79±1.64μm, and Residual: Ax: 42 μm, Lat: 110 μm. The estimation is, thus, sufficiently accurate to correct shifts down to the 10 μm capillary level. A motion-corrected image compared to a non-corrected image show small vascular structures in the cortex, which are impossible to separate in the unprocessed image, but can be clearly identified in the motioncorrected image. This demonstrates that motion correction in 2D can enhance SRI quality.

Original languageEnglish
JournalIEEE International Ultrasonics Symposium, IUS
Pages (from-to)1107-1110
Number of pages4
ISSN1948-5719
DOIs
Publication statusPublished - 1 Oct 2019
Event2019 IEEE International Ultrasonics Symposium, IUS 2019 - Glasgow, United Kingdom
Duration: 6 Oct 20199 Oct 2019

Conference

Conference2019 IEEE International Ultrasonics Symposium, IUS 2019
CountryUnited Kingdom
CityGlasgow
Period06/10/201909/10/2019

Event

2019 IEEE International Ultrasonics Symposium, IUS 2019

06/10/201909/10/2019

Glasgow, United Kingdom

Event: Conference

ID: 59155803