Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Three-dimensional ultrasound improves the accuracy of diameter measurement of the residual sac in EVAR patients

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Cutdown Technique is Superior to Fascial Closure for Femoral Artery Access after Elective Endovascular Aortic Repair

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. EJVES, the Leading Journal in Vascular Surgery, is One of the Numerous Scientific Pillars of the ESVS

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Supervised Trainee Led Open Vascular Surgery Procedures Should Be "Part" of Modern Training Curricula!

    Research output: Contribution to journalComment/debateResearchpeer-review

  1. Clinical validation of three-dimensional ultrasound for abdominal aortic aneurysm

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Carotid Intima-Media Thickness Versus Carotid Plaque Burden for Predicting Cardiovascular Risk

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Palliative Prostate Artery Embolization for Prostate Cancer: A Case Series

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
Discrepancy between maximum diameters obtained with two-dimensional ultrasound and computed tomography (CT) after endovascular aneurysm repair (EVAR) is well known. The maximal diameter is ideally measured perpendicular to the centerline, a methodology so far only feasible with three-dimensional (3D) CT and magnetic resonance angiography (MRA). We aimed to investigate the agreement between 3D ultrasound and 3D CT and to determine reproducibility measures.
Original languageEnglish
JournalEuropean journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
Volume46
Issue number5
Pages (from-to)525-32
Number of pages8
ISSN1078-5884
DOIs
Publication statusPublished - Nov 2013

    Research areas

  • Aged, Aged, 80 and over, Aortic Aneurysm, Abdominal, Aortography, Blood Vessel Prosthesis Implantation, Endovascular Procedures, Female, Humans, Image Interpretation, Computer-Assisted, Imaging, Three-Dimensional, Male, Middle Aged, Observer Variation, Predictive Value of Tests, Prospective Studies, Reproducibility of Results, Tomography, X-Ray Computed, Treatment Outcome, Ultrasonography, Interventional

ID: 42204217