Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
E-pub ahead of print

The test-retest reliability of individualized VO2peak test modalities in people with spinal cord injury undergoing rehabilitation

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Gender, class, employment status and social mobility following spinal cord injury in Denmark, the Netherlands, Norway and Switzerland

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Epidemiological characteristics and early complications after spinal cord injury in Former Yugoslav Republic of Macedonia

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. The 2019 revision of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI)-What's new?

    Research output: Contribution to journalEditorialResearchpeer-review

View graph of relations

STUDY DESIGN: Test-retest study.

OBJECTIVE: To describe the test-retest reliability of an individualized approach for peak oxygen uptake (VO2peak) testing in a clinical context, accommodating inpatients with heterogeneous levels of physical functioning.

SETTING: Inpatient rehabilitation.

METHOD: Test-retest on two types of devices (recumbent stepper and arm-crank ergometer) with two predefined protocols of varying load increments on each device. No participants performed all four test modalities. VO2peak, respiratory exchange ratio (RER), peak workload, and the reason for termination were reported. Of 23 participants included, 21 completed the test-retest procedure. Participants were inpatients, ≥18 years, who sustained a spinal cord injury (SCI) within the last 12 months at the time of admission. The median age was 52 years and 74% were male. Median time since injury at the time of the first test (T1) was 5.5 months. Seventeen were classified as American Spinal Injury Association Impairment Scale D. Intraclass correlation coefficients (ICC) and Bland-Altman plots for VO2peak was calculated to determine intra- and intertester reliability of VO2peak.

RESULTS: Mean VO2peak obtained at T1 was 1.91 L/min (95%CI: 1.31-2.51); 1.26 L/min and 2.69 L/min for the recumbent stepper protocols; 0.61 L/min and 1.39 L/min for the arm-crank ergometer protocols. ICC for intra- and intertester reliability was 0.997 (95%CI: 0.986-0.999) and 0.994 (95%CI: 0.978-0.998) respectively. Bland-Altman plots showed a mean difference of -0.005 (SD 0,12) for overall test-retest.

CONCLUSION: Test-retest reliability was high. Mean VO2peak at discharge from rehabilitation was higher than previously reported and individualized test modalities seemed to yield more optimal results in a heterogenous and representative sample during rehabilitation.

Original languageEnglish
JournalSpinal Cord
ISSN1362-4393
DOIs
Publication statusE-pub ahead of print - 4 Sep 2020

ID: 60794124