The central blood volume as measured by thoracic electrical impedance and plasma proANP is not compromised by donation of 900 mL of blood in men

Mikkel Gybel-Brask, Nikolai Baastrup Nordsborg, Jens P Goetze, Pär I Johansson, Niels H Secher, Jacob Bejder

Abstract

OBJECTIVES: To evaluate whether the donation of 900 mL of blood reduces the central blood volume (CBV) assessed by thoracic electrical impedance (TI) and plasma pro-atrial natriuretic peptide (proANP).

BACKGROUND: Donation of 450 mL of blood carries a 1% risk of a vasovagal reaction. Withdrawal of 900 mL of blood decreases cardiac output; however, the effect on CBV remains unknown.

METHODS/MATERIALS: A randomised, single-blinded, placebo-controlled, crossover design was used, where 21 healthy semi-recumbent men donated 2 × 450 mL blood or were sham-phlebotomised. Changes in CBV were estimated by proANP and TI at 1.5 (TI1.5 ) and 100 (TI100 ) kHz, reflecting extracellular volume and (regional) total body water, respectively, and the index value (IDX; 1/T1.5 -1/TI100 ) was used to estimate changes in intracellular (red cell) volume. Systolic, diastolic and mean arterial blood pressure; heart rate; stroke volume; cardiac output; and systemic vascular resistance were monitored. After completion of the study, 1000 mL of isotonic saline was infused.

RESULTS: Changes (mean% ± SD) in TI1.5 , TI100 and IDX were similar after 450 mL (-0.2 ± 1.6%, 0.0 ± 1.1%, -0.4 ± 10.1%) and 900 mL (0.1 ± 1.6%, 0.2 ± 1.5% and -2.0 ± 15.8%) of blood donation compared to after a sham donation of 450 mL (-0.9 ± 1.2%, -0.5 ± 1.5% and -0.1 ± 6.1%) and 900 mL (-1.2 ± 1.5%, -0.6 ± 1.3% and 0.5 ± 9.9%). In addition, changes in plasma proANP were similar after 450 and 900 mL of blood donation (-0.8 ± 6.7% and -7.6 ± 7.9%) as after sham donations (1.3 ± 7.3% and -4.5 ± 5.6%). Monitoring haemodynamic variables revealed that stroke volume decreased after the donation of 900 mL of blood (-12 ± 12 mL) compared to sham donations.

CONCLUSION: During a 900-mL blood loss in semi-recumbent men, CBV measured by TI and plasma proANP is not affected.

Original languageEnglish
JournalTransfusion medicine (Oxford, England)
Volume30
Issue number6
Pages (from-to)450-455
Number of pages6
ISSN0958-7578
DOIs
Publication statusPublished - Dec 2020

Fingerprint

Dive into the research topics of 'The central blood volume as measured by thoracic electrical impedance and plasma proANP is not compromised by donation of 900 mL of blood in men'. Together they form a unique fingerprint.

Cite this