Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Test-retest repeatability of the pupil light response to blue and red light stimuli in normal human eyes using a novel pupillometer

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Depletion of ATP Limits Membrane Excitability of Skeletal Muscle by Increasing Both ClC1-Open Probability and Membrane Conductance

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Probing Context-Dependent Modulations of Ipsilateral Premotor-Motor Connectivity in Relapsing-Remitting Multiple Sclerosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Functional Loss After Meningitis-Evaluation of Vestibular Function in Patients With Postmeningitic Hearing Loss

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Mitochondrial Function in Gilles de la Tourette Syndrome Patients With and Without Intragenic IMMP2L Deletions

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Pupillary light responses in type 1 and type 2 diabetics with and without retinopathy

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Melanopsin-mediated pupillary light reflex and sleep quality in patients with normal tension glaucoma

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Optos wide-field imaging versus conventional camera imaging in Danish patients with type 2 diabetes

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
In this study, we evaluated the repeatability of pupil responses to colored light stimuli in healthy subjects using a prototype chromatic pupillometer. One eye of 10 healthy subjects was tested twice in the same day using monochromatic light exposure at two selected wavelengths (660 and 470 nm, intensity 300 cd/m(2)) presented continuously for 20 s. Pupil responses were recorded in real-time before, during, and after light exposure. Maximal contraction amplitude and sustained contraction amplitude were calculated. In addition, we quantified the summed pupil response during continuous light stimulation as the total area between a reference line representing baseline pupil size and the line representing actual pupil size over 20 s (area under the curve). There was no significant difference in the repeated measure compared to the first test for any of the pupil response parameters. In conclusion, we have developed a novel prototype of color pupillometer which demonstrates good repeatability in evoking and recording the pupillary response to a bright blue and red light stimulus.
Original languageEnglish
JournalFrontiers in Neurology
Volume2
Pages (from-to)10
ISSN1664-2295
DOIs
Publication statusPublished - 2011

ID: 33183363