Technical note: DoseMapper - A validated GUI based exact numerical modelling method of shielding in PET/CT facilities

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Individualized estimates of overall survival in radiation therapy plan optimization - A concept study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Modeling tumor control probability for spatially inhomogeneous risk of failure based on clinical outcome data

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Comment on "Characterization of the Exradin W1 scintillator for use in radiotherapy" [Med. Phys. 42, 297-304 (2015)]

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Successful performance of pediatric renography does not require sedation

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Successful paediatric renography does not require sedation

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Neodymium-140 DOTA-LM3: Evaluation of anGenerator for PET with a Non-Internalizing Vector

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. In Vivo Radionuclide Generators for Diagnostics and Therapy

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

PURPOSE: To provide a faster and more intuitive way of designing shielding for PET facilities, while still relying on the principles of the AAPM 108 Taskforce guidelines, as well as illustrating the calculation output using dose maps that are easily evaluated.

METHODS: A graphical user interface was developed, implementing an inverse AAPM method, wherein radiation sources and shield barriers are manually defined. Simulations are calculated using a user defined control mesh grid. DoseMapper simulations were verified against manual calculations using the AAPM guidelines, as well as compared with in-situ dose rate measurements using four different dosemeters.

RESULTS: DoseMapper simulations were virtually identical to manual calculations using AAPM guidelines, with a maximum relative error of <0.01%. Comparison with in-situ measurements showed that DoseMapper simulated dose rates in all instances are higher than what can be measured, ensuring no unintended hotspots can be overlooked in the shielding design.

CONCLUSIONS: DoseMapper is an easy to use implementation of the AAPM 108 Taskforce principles that allows for a rapid iterative design process of shielding in PET facilities, and the resulting maps of dose rate and annual accumulated dose serve as clear documentation for the design. This article is protected by copyright. All rights reserved.

Original languageEnglish
JournalMedical Physics
Volume44
Issue number11
Pages (from-to)6053-6060
ISSN0094-2405
DOIs
Publication statusPublished - 1 Nov 2017