Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Surveillance for hemodialysis access stenosis: usefulness of ultrasound vector volume flow

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Rating scale for the assessment of competence in ultrasound-guided peripheral vascular access - a Delphi Consensus Study

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Current use of ultrasound for central vascular access in children and infants in the Nordic countries--a cross-sectional study

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Catheter-based flow measurements in hemodialysis fistulas - Bench testing and clinical performance

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Endovascular treatment of hemodialysis arteriovenous fistulas: is immediate post-interventional blood flow a predictor of patency

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Palliative Prostate Artery Embolization for Prostate Cancer: A Case Series

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Prostate Artery Embolization for Lower Urinary Tract Symptoms in Men Unfit for Surgery

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Increased risk of Staphylococcus aureus bacteremia in hemodialysis-A nationwide study

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Portable Vector Flow Imaging Compared with Spectral Doppler Ultrasonography

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. Prostate artery embolisation for benign prostatic hyperplasia: a systematic review and meta-analysis

    Research output: Contribution to journalReviewResearchpeer-review

View graph of relations

PURPOSE: To investigate if ultrasound vector-flow imaging (VFI) is equal to the reference method ultrasound dilution technique (UDT) in estimating volume flow and changes over time in arteriovenous fistulas (AVFs) for hemodialysis.

MATERIALS AND METHODS: From January 2014 to January 2015, patients with end-stage renal disease and matured functional AVFs were consecutively solicited to participate in this prospective study. All patients were included after written informed consent and approval by the National Committee on Biomedical Research Ethics and the local Ethics Committee (journal no. H-4-2014-FSP). VFI and UDT measurements were performed monthly over a six-month period. Nineteen patients were included in the study. VFI measurements were performed before dialysis, and UDT measurements after. Statistical analyses were performed with Bland-Altman plot, Student's t-test, four-quadrant plot, and regression analysis. Repeated measurements and precision analysis were used for reproducibility determination.

RESULTS: Precision measurements for UDT and VFI were 32% and 20%, respectively (p = 0.33). Average volume flow measured with UDT and VFI were 1161 mL/min (±778 mL/min) and 1213 mL/min (±980 mL/(min), respectively (p = 0.3). The mean difference was -51 mL/min (CI: -150 mL/min to 46 mL/min) with limits of agreement from -35% to 54%, with a strong correlation (r2 = 0.87). A large change in volume flow between dialysis sessions detected by UDT was confirmed by VFI (p = 0.0001), but the concordance rate was poor (0.72).

CONCLUSIONS: VFI is an acceptable method for volume flow estimation and volume flow changes over time in AVFs.

Original languageEnglish
JournalThe journal of vascular access
Volume17
Issue number6
Pages (from-to)483-488
Number of pages6
ISSN1129-7298
DOIs
Publication statusPublished - 2 Nov 2016