Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia

Jens D Hove, Klaus F Kofoed, Hsiao M Wu, Søren Holm, Lars Friberg, Christian Meyer, Jan Aldershvile, Birger Hesse, Henning Kelbaek

7 Citations (Scopus)

Abstract

The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia.
Original languageEnglish
JournalJournal of Nuclear Cardiology
Volume10
Issue number1
Pages (from-to)28-33
Number of pages6
ISSN1071-3581
DOIs
Publication statusPublished - 2003

Keywords

  • Adult
  • Aged
  • Ammonia
  • Cardiac Catheterization
  • Cardiac Output
  • Coronary Circulation
  • Heart Failure
  • Heart Transplantation
  • Humans
  • Linear Models
  • Male
  • Middle Aged
  • Nitrogen Radioisotopes
  • Observer Variation
  • Reproducibility of Results
  • Thermodilution
  • Tomography, Emission-Computed

Fingerprint

Dive into the research topics of 'Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia'. Together they form a unique fingerprint.

Cite this