Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Simulation of advanced cataract surgery - validation of a newly developed test

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{8b9a2e06d5a8470ab1448bda5ee01a3a,
title = "Simulation of advanced cataract surgery - validation of a newly developed test",
abstract = "PURPOSE: To develop and investigate an Eyesi simulator-based test for the more experienced cataract surgeon for evidence of validity.METHODS: The study was a prospective interventional cohort study and carried out at the Copenhagen Academy for Medical Education and Simulation. The Eyesi Simulator was used for the test which was developed by three expert cataract surgeons. Ten cataract surgeons (>250 surgeries performed) and ten ophthalmic residents performed two repetitions of the test. The test consisted of four modules: Iris Expansion Ring insertion - level 1, Iris Expansion Ring extraction - level 2, Capsulorhexis - level 3 and Anterior Vitrectomy - level 6.RESULTS: Internal consistency reliability showed Cronbach's alpha of 0.63. Test-retest reliabilities were significant for Iris Expansion Ring extraction - level 2 (p = 0.012) and Capsulorhexis - level 3 (p = 0.018). Differences between the two groups were only significant in both repetitions for the Iris Expansion Ring extraction - level 2 (p < 0.001 and p = 0.041, respectively). Furthermore, we found a statistically significant difference between the mean module scores for novices and the more experienced surgeons for Iris Expansion Ring insertion - level 1 (p = 0.021) and Capsulorhexis - level 3 (p = 0.019) in the first repetition.CONCLUSION: The investigated modules show evidence of validity within several aspects of Messick's framework. However, the evidence is not strong enough to apply the test for certification purposes of cataract surgeons, but the modules may still be relevant in the training of advanced cataract surgical procedures.",
author = "{Forslund Jacobsen}, Mads and Lars Konge and {la Cour}, Morten and Lars Holm and Hadi Kjaerbo and Birgitte Moldow and Saleh, {George M} and Thomsen, {Ann Sofia Skou}",
note = "{\textcopyright} 2020 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.",
year = "2020",
month = nov,
doi = "10.1111/aos.14439",
language = "English",
volume = "98",
pages = "687--692",
journal = "Acta Ophthalmologica",
issn = "1755-375X",
publisher = "Wiley-Blackwell Munksgaard",
number = "7",

}

RIS

TY - JOUR

T1 - Simulation of advanced cataract surgery - validation of a newly developed test

AU - Forslund Jacobsen, Mads

AU - Konge, Lars

AU - la Cour, Morten

AU - Holm, Lars

AU - Kjaerbo, Hadi

AU - Moldow, Birgitte

AU - Saleh, George M

AU - Thomsen, Ann Sofia Skou

N1 - © 2020 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.

PY - 2020/11

Y1 - 2020/11

N2 - PURPOSE: To develop and investigate an Eyesi simulator-based test for the more experienced cataract surgeon for evidence of validity.METHODS: The study was a prospective interventional cohort study and carried out at the Copenhagen Academy for Medical Education and Simulation. The Eyesi Simulator was used for the test which was developed by three expert cataract surgeons. Ten cataract surgeons (>250 surgeries performed) and ten ophthalmic residents performed two repetitions of the test. The test consisted of four modules: Iris Expansion Ring insertion - level 1, Iris Expansion Ring extraction - level 2, Capsulorhexis - level 3 and Anterior Vitrectomy - level 6.RESULTS: Internal consistency reliability showed Cronbach's alpha of 0.63. Test-retest reliabilities were significant for Iris Expansion Ring extraction - level 2 (p = 0.012) and Capsulorhexis - level 3 (p = 0.018). Differences between the two groups were only significant in both repetitions for the Iris Expansion Ring extraction - level 2 (p < 0.001 and p = 0.041, respectively). Furthermore, we found a statistically significant difference between the mean module scores for novices and the more experienced surgeons for Iris Expansion Ring insertion - level 1 (p = 0.021) and Capsulorhexis - level 3 (p = 0.019) in the first repetition.CONCLUSION: The investigated modules show evidence of validity within several aspects of Messick's framework. However, the evidence is not strong enough to apply the test for certification purposes of cataract surgeons, but the modules may still be relevant in the training of advanced cataract surgical procedures.

AB - PURPOSE: To develop and investigate an Eyesi simulator-based test for the more experienced cataract surgeon for evidence of validity.METHODS: The study was a prospective interventional cohort study and carried out at the Copenhagen Academy for Medical Education and Simulation. The Eyesi Simulator was used for the test which was developed by three expert cataract surgeons. Ten cataract surgeons (>250 surgeries performed) and ten ophthalmic residents performed two repetitions of the test. The test consisted of four modules: Iris Expansion Ring insertion - level 1, Iris Expansion Ring extraction - level 2, Capsulorhexis - level 3 and Anterior Vitrectomy - level 6.RESULTS: Internal consistency reliability showed Cronbach's alpha of 0.63. Test-retest reliabilities were significant for Iris Expansion Ring extraction - level 2 (p = 0.012) and Capsulorhexis - level 3 (p = 0.018). Differences between the two groups were only significant in both repetitions for the Iris Expansion Ring extraction - level 2 (p < 0.001 and p = 0.041, respectively). Furthermore, we found a statistically significant difference between the mean module scores for novices and the more experienced surgeons for Iris Expansion Ring insertion - level 1 (p = 0.021) and Capsulorhexis - level 3 (p = 0.019) in the first repetition.CONCLUSION: The investigated modules show evidence of validity within several aspects of Messick's framework. However, the evidence is not strong enough to apply the test for certification purposes of cataract surgeons, but the modules may still be relevant in the training of advanced cataract surgical procedures.

U2 - 10.1111/aos.14439

DO - 10.1111/aos.14439

M3 - Journal article

C2 - 32304357

VL - 98

SP - 687

EP - 692

JO - Acta Ophthalmologica

JF - Acta Ophthalmologica

SN - 1755-375X

IS - 7

ER -