Simulating effects of brain atrophy in longitudinal PET imaging with an anthropomorphic brain phantom

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Comparison of 11 automated PET segmentation methods in lymphoma

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Optimized MLAA for quantitative non-TOF PET/MR of the brain

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Comment on: 'A Poisson resampling method for simulating reduced counts in nuclear medicine images'

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Multimodal Image Analysis of Apparent Brain Age Identifies Physical Fitness as Predictor of Brain Maintenance

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Influence of visual feedback, hand dominance and sex on individuated finger movements

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Subjective cognitive complaints in patients with stress-related exhaustion disorder: a cross sectional study

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Educational attainment does not influence brain aging

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

In longitudinal positron emission tomography (PET), the presence of volumetric changes over time can lead to an overestimation or underestimation of the true changes in the quantified PET signal due to the partial volume effect (PVE) introduced by the limited spatial resolution of existing PET cameras and reconstruction algorithms. Here, a 3D-printed anthropomorphic brain phantom with attachable striata in three sizes was designed to enable controlled volumetric changes. Using a method to eliminate the non-radioactive plastic wall, and manipulating BP levels by adding different number of events from list-mode acquisitions, we investigated the artificial volume dependence of BP due to PVE, and potential bias arising from varying BP. Comparing multiple reconstruction algorithms we found that a high-resolution ordered-subsets maximization algorithm with spatially variant point-spread function resolution modeling provided the most accurate data. For striatum, the BP changed by 0.08% for every 1% volume change, but for smaller volumes such as the posterior caudate the artificial change in BP was as high as 0.7% per 1% volume change. A simple gross correction for striatal volume is unsatisfactory, as the amplitude of the PVE on the BP differs depending on where in the striatum the change occurred. Therefore, to correctly interpret age-related longitudinal changes in the BP, we must account for volumetric changes also within a structure, rather than across the whole volume. The present 3D-printing technology, combined with the wall removal method, can be implemented to gain knowledge about the predictable bias introduced by the PVE differences in uptake regions of varying shape.

Original languageEnglish
JournalPhysics in Medicine and Biology
Volume62
Issue number13
Pages (from-to)5213-5227
Number of pages15
ISSN0031-9155
DOIs
Publication statusPublished - 7 Jul 2017