Repeatability and Reproducibility of Neonatal Echocardiography: The Copenhagen Baby Heart Study

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Diagnostic Potential of Intracardiac Echocardiography in Patients with Suspected Prosthetic Valve Endocarditis

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Exercise Hemodynamics After Aortic Valve Replacement for Severe Aortic Stenosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Interaction of Left Ventricular Remodeling and Regional Dyssynchrony on Long-Term Prognosis after Cardiac Resynchronization Therapy

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Tissue-Doppler assessment of cardiac left ventricular function during short-term adjuvant epirubicin therapy for breast cancer

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Differences in mortality in patients undergoing surgery for infective endocarditis according to age and valvular surgery

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Left-sided heart disease and risk of death in patients with end-stage kidney disease receiving haemodialysis: an observational study

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Fractional Flow Reserve Guided PCI in Patients With and Without Left Ventricular Hypertrophy: a DANAMI-3-PRIMULTI Sub-study

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Accelerated treatment of endocarditis-The POET II trial: Rationale and design of a randomized controlled trial

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: The Copenhagen Baby Heart Study (CBHS) is a population-based cohort study of neonates (N = 25,000), including echocardiography. Echocardiography in neonates is mainly focused on congenital heart disease (CHD), whereas general aspects of cardiac dimensions and function in neonates without CHD remain to be further addressed.

PURPOSE: This study was conducted to assess the reliability of neonatal echocardiography and validity of echocardiographic methods used in the CBHS.

METHODS: Reliability and agreement were tested for two-dimensional (2D), M-mode, spectral Doppler, and tissue velocity echocardiography for the following. (1) Measurements: seven sonographers independently performed two measurement rounds: (a) measurement of the same 50 echocardiograms (n = 350 echocardiograms measured) and (b) repeated measurement of 25 of the 50 echocardiograms (n = 175 echocardiograms measured). (2) Acquisition: four sonographers independently performed two rounds of echocardiographic acquisition and subsequent measurement of the same 22 neonates (n = 176 acquisitions and measures). Intra- and interobserver variabilities were assessed by determinations of coefficient of variation (CV), intraclass correlation coefficient (ICC), Bland-Altman plot, and 95% limits of agreement.

RESULTS: (1) Measurements: we found intra- and interobserver ICC ≥ 0.67 for 2D parameters, except for left ventricular (LV) wall thicknesses and LV diameter (interobserver); ICC ≥ 0.84 for tricuspid annular plane systolic excursion (TAPSE); ICC ≥ 0.93 for pulsed-wave Doppler (PW); ICC ≥ 0.84 for continuous-wave Doppler; and ICC ≥ 0.87 for tissue velocity parameters. We found CV < 15% for all parameters except LV wall thicknesses. (2) Acquisition: we found intra- and interobserver ICC ≥ 0.69 for 2D parameters, except for LV wall thicknesses, aortic valve annulus (interobserver), and LV end-systolic diameter (interobserver); ICC = 0.45-0.49 for TAPSE; ICC = 0.48-0.64 for PW; and ICC ≥ 0.70 for continuous wave. We found CV < 15% for all parameters.

CONCLUSIONS: Reliability of echocardiographic measurements and acquisition of cardiac dimensions and function were good for most parameters but lower for TAPSE (acquisition) and PW Doppler (acquisition) and poor for LV wall thicknesses. In general, echocardiography of cardiac dimensions and function in the neonate is reliable.

Original languageEnglish
JournalJournal of the American Society of Echocardiography
Volume32
Issue number7
Pages (from-to)895-905.e2
ISSN0894-7317
DOIs
Publication statusPublished - 1 Jul 2019

    Research areas

  • Acquisition, Agreement, Echocardiography, Measurements, Neonate, Reliability

ID: 57663533