Performance Stability and Interrater Reliability of Culturally Adapted 10-Meter Walking Test for Danes with Neurological Disorders

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Computer-Based Cognitive Rehabilitation in Patients with Visuospatial Neglect or Homonymous Hemianopia after Stroke

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Social Inequality by Income in Short- and Long-Term Cause-Specific Mortality after Stroke

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Self-Reported Physical Activity and Cardiovascular Disease Risk Factors in Patients with Lacunar Stroke

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Secondary Stroke Prophylaxis with Clopidogrel Produces Sufficient Antiplatelet Response

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: The 10-meter Walking Test (10MWT) is often used to assess people with, e.g., stroke, but often using different procedures. The aims of this study were to translate the 10MWT into Danish, to determine the number of trials needed to achieve performance stability, and to examine the interrater reliability and agreement of the 10MWT in people with neurological disorders.

METHODS: Translation followed international recommendations, and evaluated in a consecutive sample of 50 people with a neurological disorder. All participants performed 5 timed 10MWT trials (usual speed) with 20-seconds rest intervals between trials, supervised by a physical therapist. A second session was conducted with another physical therapist, separated with a mean (SD) of 2.7 (0.9) hours. The order of raters was randomized and they were blinded to each other's ratings. Repeated measures ANOVA determined performance stability, while ICC1.1, standard error of measurement (SEM), and minimal detectable change (MDC95) determined reproducibility.

RESULTS: Participant's improved their 10MWT scores significantly between the first and second trial only. The faster of the 2 trials took a mean of 11.95 (5.40) seconds, and significantly (P < 0.001) faster than the slowest; mean of 12.80 (6.13) seconds. The intraclass correlation coefficient (ICC; 95% confidence interval), SEM, and MDC, based on the fastest of 2 trials, were 0.97 (0.95-0.98), 0.06 m/s, and 0.17 m/s, respectively, and with no systematic between rater's bias.

CONCLUSIONS: We suggest that the faster of 2 timed trials be recorded for the 10MWT in people with neurological disorders, as we found excellent interrater reliability and low measurement error using this score.

Original languageEnglish
JournalJournal of stroke and cerebrovascular diseases : the official journal of National Stroke Association
Volume28
Issue number9
Pages (from-to)2459-2467
Number of pages9
ISSN1052-3057
DOIs
Publication statusPublished - Sep 2019

    Research areas

  • Outcome assessment (health care), gait speed, rehabilitation, reproducibility of results, walking, Predictive Value of Tests, Humans, Middle Aged, Male, Time Factors, Aged, 80 and over, Translating, Female, Reproducibility of Results, Cultural Characteristics, European Continental Ancestry Group, Walking, Denmark/epidemiology, Nervous System Diseases/diagnosis, Exercise Tolerance, Aged, Walking Speed, Health Status, Walk Test, Observer Variation