Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Percutaneous retrieval of an embolized left atrial appendage closure device from the left atrium in a patient with previous MitraClips

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Non-diagnostic autopsy findings in sudden unexplained death victims

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Phenome-wide association analysis of LDL-cholesterol lowering genetic variants in PCSK9

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Contemporary management of severe symptomatic bicuspid aortic valve stenosis: the BiTri Registry

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. State-of-the-art preclinical testing of the OMEGATM left atrial appendage occluder

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Threshold for calcium volume evaluation in patients with aortic valve stenosis: correlation with Agatston score

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Spontaneous thrombosis of a transcatheter aortic valve replacement-induced aortic root pseudoaneurysm

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

BACKGROUND: Left atrial appendage closure is increasingly used. LAA closure procedures can rarely be complicated by device embolization, typically towards the aorta. In this case report, we describe the successful percutaneous retrieval of an embolized Amulet device from the left atrium in a patient with previous MitraClips.

CASE PRESENTATION: By guidance of intracardiac echocardiography (ICE) and under local anaesthesia, two guiding systems were introduced into the LA; one to stabilize the device against the lateral LA wall and one large system to retrieve the device. However, the LAA closure device was finally snared by a three-loop snare and pulled across the interatrial septum (IAS) without taking the device into a protective guiding sheath - and this without tearing the IAS.

CONCLUSIONS: In conclusion, percutaneous retrieval of an embolized LAA closure device from the LA is feasible by transseptal approach under local anaesthesia and with ICE guidance.

Original languageEnglish
JournalBMC Cardiovascular Disorders
Volume19
Issue number1
Pages (from-to)196
ISSN1471-2261
DOIs
Publication statusPublished - 14 Aug 2019

ID: 59143065