Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Parallel plate model for trabecular bone exhibits volume fraction-dependent bias

Research output: Contribution to journalJournal articlepeer-review

  1. Constitutive relationships of fabric, density, and elastic properties in cancellous bone architecture

    Research output: Contribution to journalJournal articlepeer-review

  2. Connectivity and the elastic properties of cancellous bone

    Research output: Contribution to journalJournal articlepeer-review

  3. Three-dimensional methods for quantification of cancellous bone architecture

    Research output: Contribution to journalReviewpeer-review

  4. Three-dimensional reconstruction of entire vertebral bodies

    Research output: Contribution to journalJournal articlepeer-review

  • J S Day
  • M Ding
  • A Odgaard
  • D R Sumner
  • I Hvid
  • H Weinans
View graph of relations

Unbiased stereological methods were used in conjunction with microcomputed tomographic (micro-CT) scans of human and animal bone to investigate errors created when the parallel plate model was used to calculate morphometric parameters. Bone samples were obtained from the human proximal tibia, canine distal femur, rat tail, and pig spine and scanned in a micro-CT scanner. Trabecular thickness, trabecular spacing, and trabecular number were calculated using the parallel plate model. Direct thickness, and spacing and connectivity density were calculated using unbiased three-dimensional methods. Both thickness and spacing calculated using the plate model were well correlated to the direct three-dimensional measures (r(2) = 0. 77-0.92). The correlation between trabecular number and connectivity density varied greatly (r(2) = 0.41-0.94). Whereas trabecular thickness was consistently underestimated using the plate model, trabecular spacing was underestimated at low volume fractions and overestimated at high volume fractions. Use of the plate model resulted in a volume-dependent bias in measures of thickness and spacing (p < 0.001). This was a result of the fact that samples of low volume fraction were much more "rod-like" than those of the higher volume fraction. Our findings indicate that the plate model provides biased results, especially when populations with different volume fractions are compared. Therefore, we recommend direct thickness measures when three-dimensional data sets are available.

Original languageEnglish
JournalBone
Volume27
Issue number5
Pages (from-to)715-20
Number of pages6
ISSN8756-3282
DOIs
Publication statusPublished - Nov 2000
Externally publishedYes

    Research areas

  • Adolescent, Adult, Aged, Aged, 80 and over, Animals, Bone and Bones/anatomy & histology, Dogs, Humans, Middle Aged, Rats, Swine, Tomography, X-Ray Computed

ID: 78347883