Skip to main navigation Skip to search Skip to main content

Operative findings in recurrent hernia after a Lichtenstein procedure.

M Bay-Nielsen, P Nordin, E Nilsson, H Kehlet, NN NN

69 Citations (Scopus)

Abstract

BACKGROUND: Recurrence after inguinal herniorraphy continues to be a problem, although the Lichtenstein technique (anterior, open fixated sheet mesh) is associated with reduced recurrence rates. Recurrence after Lichtenstein repair is suspected to be caused by insufficient fixation and overlap at the pubic tubercle. METHODS: A review was made of 87 records from operations for recurrence after a previous Lichtenstein procedure, based upon national and large area data bases, recording 95% (Denmark) and 50% (Sweden) of all inguinal hernia operations. RESULTS: Direct recurrences were found in 62%, whereas the remaining recurrences were either indirect (17%), femoral (13%), or other/unclassified (8%). CONCLUSION: The most plausible explanation for the development of the direct recurrences is an insufficient medial mesh fixation and overlap over the pubic tubercle. Avoidance of more than half of the recurrences after the Lichtenstein repair may be obtained by increased attention to this specific technical aspect of the operation.
Translated title of the contributionOperative findings in recurrent hernia after a Lichtenstein procedure.