Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Objective and Subjective Outcome of a New Transcutaneous Bone Conduction Hearing Device: Half-year Follow-up of the First 12 Nordic Implantations

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Stereologic Investigation of Mastoid Air Cell Geometry: Volume, Surface Area, and Anisotropy

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Cochlear MRI Signal Change Following Vestibular Schwannoma Resection Depends on Surgical Approach

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Intratympanic Steroid for Menière's Disease: A Systematic Review

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Cochlear MRI Signal Change Following Vestibular Schwannoma Resection Depends on Surgical Approach

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Association of SLC26A4 mutations, morphology, and hearing in pendred syndrome and NSEVA

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Knogleforankrede høreapparater og aktive mellemøreimplantater

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

OBJECTIVE: To examine the objective and subjective outcome of a new transcutaneous bone conduction hearing device.

STUDY DESIGN: Prospective, consecutive case series.

PATIENTS: Twelve patients were implanted. Eight patients had a conductive/mixed (con/mix) hearing loss. Four had single sided deafness.

MAIN OUTCOME MEASURES: At half-year follow-up, aided and unaided sound field hearing was evaluated by 1) warble tone thresholds, 2) pure-tone average (PTA4), 3) speech discrimination score (SDS) in quiet, and 4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective outcome was evaluated by three questionnaires: 1) International Outcome Inventory for Hearing Aids, 2) Speech, Spatial and Qualities of Hearing Scale 12, and 3) a questionnaire on frequency and duration of use.

RESULTS: No major complications occurred. The mean aided PTA4 was lowered by 23dB. SDS was increased by 40% at 50dB, by 34% at 65dB, and by 12% at 80 dB SPL. SRT50% in noise improved 5.2 dB. 58% of the patients used the device daily and 83% at least 5 days a week. 50% used the device ≥ 8 hours and 75% ≥ 4  hours a day. Mean International Outcome Inventory for Hearing Aids score was 3.7, corresponding to beneficial outcome. In Speech, Spatial and Qualities of Hearing Scale 12, "quality of hearing" scored especially high. The con/mix hearing loss group showed larger benefit especially in SDS, SRT50% in noise and the subjective evaluations, whereas frequency and duration of use were similar.

CONCLUSION: This study on the first 12 Nordic patients implanted with a new transcutaneous bone conduction hearing device demonstrates significant objective, as well as subjective hearing benefit. Patient satisfaction was high, as was the frequency of use.

Original languageEnglish
JournalOtology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Volume37
Issue number3
Pages (from-to)267-75
Number of pages9
ISSN1531-7129
DOIs
Publication statusPublished - Mar 2016

    Research areas

  • Adult, Aged, Bone Conduction, Female, Follow-Up Studies, Hearing Aids, Hearing Loss, Sensorineural, Hearing Tests, Humans, Male, Patient Satisfaction, Prospective Studies, Surveys and Questionnaires, Treatment Outcome, Journal Article

ID: 49660160