Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Multicenter evaluation of the QIAstat-Dx respiratory panel for detection of viruses and bacteria in nasopharyngeal swab specimens

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Early Laboratory Diagnosis of COVID-19 by Antigen Detection in Blood Samples of the SARS-CoV-2 Nucleocapsid Protein

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Comparison of 16 Serological SARS-CoV-2 Immunoassays in 16 Clinical Laboratories

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Diagnostic Accuracy of Interferon Gamma-Induced Protein 10 mRNA Release Assay for Tuberculosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Update from a twelve-year nationwide fungaemia surveillance: increasing intrinsic and acquired resistance causes concern

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. PREVALENCE OF HUMAN PAPILLOMAVIRUS IN SELF-TAKEN SAMPLES FROM SCREENING NON-ATTENDERS

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Presence of SARS-CoV-2 in semen and the impact of COVID-19 on the male reproductive system

    Research output: Contribution to journalReviewResearchpeer-review

  2. SARS-CoV-2 detection using reverse transcription strand invasion based amplification and a portable compact size instrument

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Point of care testing for infectious disease: ownership and quality

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. A non-enzymatic, isothermal strand displacement and amplification assay for rapid detection of SARS-CoV-2 RNA

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

The QIAstat-Dx Respiratory Panel (QIAstat-Dx RP) is a multiplex in vitro diagnostic test for the qualitative detection of 20 pathogens directly from nasopharyngeal swab (NPS) specimens. The assay is performed using a simple sample-toanswer platform with results available in approximately 69 min. The pathogens identified are adenovirus, coronavirus 229E, coronavirus HKU1, coronavirus NL63, coronavirus OC43, human metapneumovirus A and B, influenza A, influenza A H1, influenza A H3, influenza A H1N1/2009, influenza B, parainfluenza virus 1, parainfluenza virus 2, parainfluenza virus 3, parainfluenza virus 4, rhinovirus/enterovirus, respiratory syncytial virus A and B, Bordetella pertussis, Chlamydophila pneumoniae, and Mycoplasma pneumoniae. This multicenter evaluation provides data obtained from 1,994 prospectively collected and 310 retrospectively collected (archived) NPS specimens with performance compared to that of the BioFire FilmArray Respiratory Panel, version 1.7. The overall percent agreement between QIAstat-Dx RP and the comparator testing was 99.5%. In the prospective cohort, the QIAstat-Dx RP demonstrated a positive percent agreement of 94.0% or greater for the detection of all but four analytes: coronaviruses 229E, NL63, and OC43 and rhinovirus/enterovirus. The test also demonstrated a negative percent agreement of ≥97.9% for all analytes. The QIAstat-Dx RP is a robust and accurate assay for rapid, comprehensive testing for respiratory pathogens.

Original languageEnglish
Article numbere00155-20
JournalJournal of Clinical Microbiology
Volume58
Issue number5
Pages (from-to)1-11
Number of pages11
ISSN0095-1137
DOIs
Publication statusPublished - 23 Apr 2020

    Research areas

  • Multiplex, PCR, Respiratory

ID: 59510864