Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Morphology and Function of the Lymphatic Vasculature in Patients With a Fontan Circulation

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Morphology

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Echocardiographic Predictors of Mortality in Women With Heart Failure With Reduced Ejection Fraction

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Infants with congenital heart defects have reduced brain volumes

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Exploring patient experiences in the student outpatient clinic - A contribution to learning

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Cardiac Arrhythmias and Impaired Heart Rate Variability in Older Patients With Ventricular Septal Defects

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Lymphatic Function in the Arms of Breast Cancer Patients-A Prospective Cohort Study

    Research output: Contribution to journalJournal articleResearchpeer-review

  • Sheyanth Mohanakumar
  • Niklas Telinius
  • Benjamin Kelly
  • Henrik Lauridsen
  • Donna Marie Briggs Bødtkjer
  • Michael Pedersen
  • Marc de Leval
  • Vibeke E. Hjortdal
View graph of relations
BACKGROUND:
The Fontan procedure has revolutionized the treatment of univentricular hearts. However, it is associated with severe complications such as protein-losing enteropathy, plastic bronchitis, and peripheral edema that may involve the lymphatic circulation. We aimed to assess lymphatic function and morphology in patients with a univentricular circulation.
METHODS:
The functional state of lymphatic vessels in the lower extremities of patients with a Fontan circulation (n=10) was investigated using the novel technique near-infrared fluorescence imaging and compared with an age-, sex-, and weight-matched control group of healthy volunteers (n=10). The lymphatic morphology was described using T2-weighted magnetic resonance imaging, and microvascular permeability was estimated by strain gauge plethysmography.
RESULTS:
The Fontan patients had 17% lower lymphatic pumping pressure (50±3.1 mm Hg) compared with controls (60±2.8 mm Hg; P=0.0341) and a 62% higher contraction frequency (0.8±0.1 min-1) compared with the healthy controls (0.5±0.1 min-1; P=0.0432). Velocity by which the lymph is moved and refill time after manual emptying of the lymphatic vessels showed no differences between the 2 groups. The thoracic duct was elongated 10% ( P=0.0409) and with an abnormal course in the Fontan patients compared with normal. No difference in microvascular permeability was found between the 2 groups.
CONCLUSIONS:
Patients with a Fontan circulation have an impaired lymphatic pumping capacity and morphologically changed thoracic duct. Our results indicate a challenged lymphatic vasculature in the Fontan circulation and may play a role in the pathogenesis of the complications that are seen in Fontan patients.
Original languageEnglish
Article numbere008074
JournalCirculation: Cardiovascular Imaging
Volume12
Issue number4
Number of pages15
ISSN1941-9651
DOIs
Publication statusPublished - Apr 2019
Externally publishedYes

ID: 65027347