Abstract
AIMS: Echocardiographic diastolic parameters are used to diagnose and monitor increased left ventricular filling pressure (LVFP) and we hypothesized that increased loading conditions cause increased E/e'. Our aim was to assess the effect of preload augmentation on diastolic parameters among both healthy subjects and subjects with known cardiac disease.
METHODS AND RESULTS: We included 129 subjects merged from two cohorts; one dialysis cohort (n = 47) and one infusion cohort (n = 82). Echocardiography was performed immediately before and after hemodialysis (HD) or saline infusion, under low and high loading conditions. Elevated LVFP was defined as septal E/e' ≥ 15 and/or lateral E/e' ≥ 13 at high-loading conditions. The population was divided according to elevated LVFP (n = 31) and normal LVFP (n = 98). The load difference for the population was 972 ± 460 mL, with no differences in load difference between elevated and normal LVFP (p NS). The subjects with elevated LVFP were older (63 ± 11 vs. 46 ± 16 years, p < .001), and had lower LV ejection fraction (50 ± 14 vs. 59 ± 8.1%, p < .01). After augmented preload, EDV increased in the normal LVFP group (p < .01) but remained unchanged in the elevated LVFP group (p NS). Both E and e' increased among the subjects with normal LVFP, whereas E/e' remained unchanged (∆E/e' +.1 [-.5-1.2]), p NS). Among the subjects with elevated, LVFP we observed increased E but not e', resulting in significantly increased E/e' (∆ average E/e' +2.4 [0-4.0], p < .01).
CONCLUSION: Augmented preload does not seem to affect E/e' among subjects with normal LVFP, whereas E/e' seems to increase significantly among subjects with elevated LVFP.
| Original language | English |
|---|---|
| Article number | e15917 |
| Journal | Echocardiography (Mount Kisco, N.Y.) |
| Volume | 41 |
| Issue number | 9 |
| ISSN | 0742-2822 |
| DOIs | |
| Publication status | Published - Sept 2024 |
Keywords
- diastolic dysfunction
- diastolic function
- echocardiography
- hemodialysis
- preload
- tissue Doppler imaging
Fingerprint
Dive into the research topics of 'Increased preload and echocardiographic assessment of diastolic function'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS