Impact of mean arterial pressure on sublingual microcirculation during cardiopulmonary bypass - secondary outcome from a randomised clinical trial

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. The effect of glucagon-like peptide-1 and glucagon-like peptide-2 on microcirculation: a systematic review

    Research output: Contribution to journalReviewResearchpeer-review

  2. Treatment strategies in coronary microvascular dysfunction: a systematic review of interventional studies

    Research output: Contribution to journalReviewResearchpeer-review

  3. Characterization of Relaxant Responses to Natriuretic Peptides in the Human Microcirculation In Vitro and In Vivo

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. European College of Phlebology guideline for truncal ablation

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Mechanical respiratory support in cardiogenic shock: reply

    Research output: Contribution to journalComment/debateResearchpeer-review

View graph of relations

OBJECTIVE: In this substudy of a randomised, clinical trial, we explored the sublingual microcirculation during cardiac surgery at two different levels of blood pressure. We hypothesised that a higher mean arterial pressure during cardiopulmonary bypass would cause higher Microvascular Flow Index.

METHODS: Thirty-six cardiac surgery patients undergoing coronary artery bypass grafting were included and randomised to either low (40-50 mmHg) or high (70-80 mmHg) mean arterial pressure during cardiopulmonary bypass. Sidestream Dark Field video images were recorded from the sublingual mucosa. Recordings were analysed in a blinded fashion to quantify microcirculatory variables.

RESULTS: Mean arterial pressure during cardiopulmonary bypass in the low target group was 45.0 mmHg (SD 5.3) vs. 67.2 mmHg (SD 8.9) in the high target group. We found no significant difference between the two groups in Microvascular Flow Index during cardiopulmonary bypass evaluated for all vessels: 2.91 vs. 2.90 (p = 0.82). For small vessels (< 20 micrometers), the corresponding values were 2.87 and 2.85 in the low and high target groups, respectively (p = 0.82).

CONCLUSIONS: We found no significant difference in sublingual microcirculatory flow expressed as Microvascular Flow Index according to two different levels of mean arterial pressure during cardiopulmonary bypass. This article is protected by copyright. All rights reserved.