Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Cerebral blood flow tomography with xenon-133

Research output: Contribution to journalJournal articleResearchpeer-review

  1. PET/CT for Staging; Past, Present, and Future

    Research output: Contribution to journalReviewResearchpeer-review

  2. PET/CT in Radiation Therapy Planning

    Research output: Contribution to journalReviewResearchpeer-review

  3. PET/CT Imaging and Radioimmunotherapy of Prostate Cancer

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Methodology for ventilation/perfusion SPECT

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Dopamine D(2) receptor quantification in extrastriatal brain regions using [(123)I]epidepride with bolus/infusion

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Vestibularis-schwannomers diagnostik og vaekst bedømt ved SPECT kombineret med TL-201 Thallium

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Activation-induced resetting of cerebral oxygen and glucose uptake in the rat

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Activation-induced resetting of cerebral oxygen and glucose uptak in the rat

    Research output: Contribution to journalJournal articleResearchpeer-review

  5. SPECT og PET i neurobiologien

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-133. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This article discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the 99mTc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.
Original languageEnglish
JournalSeminars in Nuclear Medicine
Volume15
Issue number4
Pages (from-to)347-56
Number of pages10
ISSN0001-2998
StatePublished - Oct 1985

    Research areas

  • Arterial Occlusive Diseases, Brain, Carotid Artery Diseases, Cerebrovascular Circulation, Cerebrovascular Disorders, Humans, Ischemic Attack, Transient, Technetium, Tomography, Emission-Computed, Xenon Radioisotopes

ID: 39049053