Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Validation of non-invasive haemodynamic methods in patients with liver disease: the Finometer and the Task Force Monitor

Research output: Contribution to journalJournal articleResearchpeer-review

DOI

  1. Myocardial perfusion assessed with cardiac computed tomography in women without coronary heart disease

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Cardiometabolic effects of antidiabetic drugs in non-alcoholic fatty liver disease

    Research output: Contribution to journalReviewResearchpeer-review

  3. I-MIBG imaging for detection of anthracycline-induced cardiomyopathy

    Research output: Contribution to journalReviewResearchpeer-review

  4. (18) F-FDG PET/CT for planning external beam radiotherapy alters therapy in 11% of 581 patients

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Enhanced processing of von Willebrand factor reflects disease severity and discriminates severe portal hypertension in cirrhosis

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. The indocyanine green retention test in cirrhosis and portal hypertension. Accuracy and relation to severity of disease

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Pronounced Coronary Arteriosclerosis in Cirrhosis: Influence on Cardiac Function and Survival?

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. Concomitant Polymyalgia Rheumatica and Large-Vessel Vasculitis Visualized on 18F-FDG PET/CT

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations

Patients with advanced cirrhosis often present a hyperdynamic circulation characterized by a decrease in systolic and diastolic blood pressure (SBP and DBP), and an increase in heart rate (HR) and cardiac output (CO). Accurate assessment of the altered circulation can be performed invasively; however, due to the disadvantages of this approach, non-invasive methods are warranted. The purpose of this study was to compare continuous non-invasive measurements of haemodynamic variables by the Finometer and the Task Force Monitor with simultaneous invasive measurements. In 25 patients with cirrhosis, SBP, DBP and HR were measured non-invasively and by femoral artery catheterization. CO was measured non-invasively and by indicator dilution technique. The non-invasive pressure monitoring was considered acceptable with a bias (accuracy) and a SD (precision) not exceeding 5 and 8 mmHg, respectively, as recommended by the Association for the Advancement of Medical Instrumentation. The accuracy and precision of the Finometer and the Task Force Monitor were as follows: SBP: -3·6 ± 17·9 and -8·9 ± 17·5 mmHg, respectively; DBP: 4·2 ± 9·6 and 1·9 ± 8·6 mmHg, respectively; HR: 2·0 ± 6·9 and 2·2 ± 6·2 bpm, respectively; and CO: 0·1 ± 1·6 and -1·0 ± 2·0 L min(-1) , respectively. The study demonstrates that the overall performances of the Finometer and the Task Force Monitor in estimating absolute values of SBP, DBP, HR and CO in patients with cirrhosis are not equivalent to the gold standard, but may have an acceptable performance with repeated measurements.

Original languageEnglish
JournalClinical Physiology and Functional Imaging
Volume38
Issue number3
Pages (from-to)384-389
ISSN1475-0961
DOIs
Publication statusPublished - May 2018

    Research areas

  • Journal Article

ID: 50285871