Research
Print page Print page
Switch language
The Capital Region of Denmark - a part of Copenhagen University Hospital
Published

Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Improving diabetes-related family functioning and mutual family involvement with co-created family dialogue tools

    Research output: Contribution to journalConference abstract in journalResearchpeer-review

  2. Characteristics associated with non-disclosure of Type 2 diabetes at work

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. A health promotion intervention targeting women with prior gestational diabetes mellitus and their families: Protocol for the Face it study

    Research output: Contribution to conferenceConference abstract for conferenceResearchpeer-review

  2. The impact of restricted gestational weight gain by dietary intervention on fetal growth in women with gestational diabetes mellitus

    Research output: Contribution to journalJournal articleResearchpeer-review

View graph of relations
Aim:  To evaluate self-reported satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy among women with pregestational diabetes. Methods:  Fifty-four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring for 6 days at median 9 (range 6-14) gestational weeks and were asked to answer a semi-structured questionnaire on patient satisfaction. Results:  Median HbA(1c) was 49 (range 34-86) mmol/mol) [6.6 (5.3-10.0) %] and duration of diabetes was 12 (0.5-37) years. Continuous glucose monitoring was used for 6 (0.5-7) days, with 43 (65%) women using continuous glucose monitoring for at least 5 days. The women experienced 2.7 (0-12) alarms per 24 h, of which approximately one third was technical alarms and one third disturbed their sleep. Sixteen women (24%) reported discomfort with continuous glucose monitoring during daytime and twelve (18%) during sleep. Many women reported improved diabetes understanding (52%) and would recommend continuous glucose monitoring to others (83%). Twenty-four patients (36%) had continuous glucose monitoring removed earlier than planned (before the intended 6 days of initial monitoring). Ten women (15%) did not wish to use continuous glucose monitoring again in pregnancy. Main causes behind early removal of continuous glucose monitoring were self-reported skin irritation, technical problems and continuous glucose monitoring inaccuracy. No differences were found in continuous glucose monitoring use, inconvenience or compliance with respect to diabetes type. Conclusions:  The majority of pregnant women with diabetes found real-time continuous glucose monitoring useful and the intervention was equally tolerated regardless of diabetes type. Nevertheless, continuous glucose monitoring was frequently removed earlier than planned, primarily because of skin irritation, technical problems and inaccuracy.
Original languageEnglish
JournalDiabetic Medicine
Volume29
Issue number2
Pages (from-to)272-7
Number of pages6
ISSN0742-3071
DOIs
Publication statusPublished - 2012

ID: 33152673