Published

A radio-high-performance liquid chromatography dual-flow cell gamma-detection system for on-line radiochemical purity and labeling efficiency determination

Research output: Contribution to journalJournal articleResearchpeer-review

  1. Separation of steroid isomers by ion mobility mass spectrometry

    Research output: Contribution to journalJournal articleResearchpeer-review

  1. Recurrent, Activating Variants in the Receptor Tyrosine Kinase DDR2 Cause Warburg-Cinotti Syndrome

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. The CAPOS mutation in ATP1A3 alters Na/K-ATPase function and results in auditory neuropathy which has implications for management

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Praktisk oftalmologi

    Research output: Chapter in Book/Report/Conference proceedingBook chapterResearchpeer-review

  4. "My child’s teacher says she can’t see properly!"

    Research output: Chapter in Book/Report/Conference proceedingBook chapterResearchpeer-review

View graph of relations

In this study, a method of determining radiochemical yield and radiochemical purity using radio-HPLC detection employing a dual-flow-cell system is evaluated. The dual-flow cell, consisting of a reference cell and an analytical cell, was constructed from two PEEK capillary coils to fit into the well of a NaI(Tl) detector. The radio-HPLC flow was directed from the injector to the reference cell allowing on-line detection of the total injected sample activity prior to entering the HPLC column. The radioactivity eluted from the column was then detected in the analytical cell. In this way, the sample will act as its own standard, a feature enabling on-line quantification of the processed radioactivity passing through the system. All data were acquired on-line via an analog signal from a rate meter using chromatographic software. The radiochemical yield and recovery could be simply and accurately determined by integration of the peak areas in the chromatogram obtained from the reference and analytical cells using an experimentally determined volume factor to correct for the effect of different cell volumes.

Original languageEnglish
JournalJournal of Chromatography A
Volume1337
Pages (from-to)128-32
Number of pages5
ISSN0021-9673
DOIs
Publication statusPublished - 11 Apr 2014

    Research areas

  • Astatine, Benzoates, Chromatography, High Pressure Liquid, Iodine Radioisotopes, Isotope Labeling, Limit of Detection, Radiopharmaceuticals, Technetium, Trimethyltin Compounds