Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients

Research output: Contribution to journalJournal articleResearchpeer-review

  1. The wound healing effect of local leukocyte platelet-rich plasma after total hip arthroplasty: A randomized controlled trial

    Research output: Contribution to journalJournal articleResearchpeer-review

  2. Patient-reported outcomes following interposition arthroplasty of the basal joint of the thumb

    Research output: Contribution to journalJournal articleResearchpeer-review

  3. Factors Associated with Increased Risk of Recurrence following Treatment of Trigger Finger with Corticosteroid Injection

    Research output: Contribution to journalJournal articleResearchpeer-review

  4. 18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI

    Research output: Contribution to journalJournal articleResearchpeer-review

  • Peter Bo Jørgensen
  • Henrik Daugaard
  • Stig Storgaard Jakobsen
  • Martin Lamm
  • Kjeld Søballe
  • Maiken Stilling
View graph of relations

Background and purpose — BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM. Patients and methods — In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55–75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs. Results — At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02–0.20) was higher than in the P group (0.25 mm, CI 0.15–0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14–20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04). Interpretation — Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.

Original languageEnglish
JournalActa Orthopaedica
Volume91
Issue number1
Pages (from-to)26-32
Number of pages7
ISSN1745-3674
DOIs
Publication statusPublished - 2 Jan 2020

ID: 66399808